9.

 

DISPLAY INFORMATION FOR ERROR CODES/FAULTS 

Fault list for microcomputer control box CS005 
Error codes are displayed on the LED display as [Err xx]. The following two numbers 
after the “Err” notation indicates the error that has occurred.  
 
The following list of error codes can be indicated on the CS005 Microcontroller. 
 

Error 
Code 

Error/Fault 
Observed 

Error/Fault 
Detection 

How to Clear 
Error/Fault 

Likely Cause for Error/Fault 

 

Power 
overvoltage 

Inside rectifier 
voltage is over 
DC255V for 10 sec. 
or more 

Inside rectifier 
voltage is under 
DC225V for 1 sec. 
or less 

 

High power supply voltage 
(AC180V or over) 

 

Excessive inertia due to 
heavy door weight 

 

Power supply 
low voltage 

Inside rectifier 
voltage is less than 
DC50V for 3 sec. or 
more 

Inside rectifier 
voltage is less 
than DC50V for 1 
sec. or more 

 

Input AC power supply is 
low voltage (AC36V or less) 

 

Motor sensor is 
abnormal 

Either motor sensor 
(U, V, W) is low or 
high for 5 sec or 
more 

Remove power. 
Wait 5 seconds 
and reconnect 
power 

 

Motor connector is missing 

 

Wire for motor sensor is 
broken 

 

Motor is out of order 

 

Motor sensor U 
is abnormal 

Motor sensor U has 
not changed for 
more than 5 sec. 
during motor 
operation 

Remove power. 
Wait 5 seconds 
and reconnect 
power 

 

Motor connector is missing 

 

Motor wire is broken 

 

Motor is out of order 

 

Motor shaft is locked 

 
Normally it does not occur

 

 

Motor sensor V 
is abnormal 

Motor sensor V has 
not changed for 
more than 5 sec. 
during motor 
operation 

Remove power. 
Wait 5 seconds 
and reconnect 
power 

 

Motor sensor W 
is abnormal 

Motor sensor W has 
not changed for 
more than 5 sec. 
during motor 
operation 

Remove power. 
Wait 5 seconds 
and reconnect 
power 

 

EEPROM is 
abnormal 

Communication to 
internal memory 
failed 

Remove power. 
Wait 5 seconds 
and reconnect 
power 

 

Memory in substrate is 
abnormal 

 

IPM is abnormal  IPM (power module) 

abnormal condition 
is more than 1 sec. 

Remove power. 
Wait 5 seconds 
and reconnect 
power 

 

Memory in substrate is 
abnormal 

 

Overload Fault 

Door under 
operation stops 
more than 2 sec. 
due to external 
pressure 

Run door though 
standard 
open/close cycle  

 

Due to obstacle and 
wearing rollers, running 
resistance is big 

 

 

 

 

 

 

 

Summary of Contents for Solic CS005

Page 1: ...ON MANUAL AUTOMATIC SLIDING DOOR OPERATOR Microcomputer Control Type MODEL CS005 Motor M005 Hypoid gear type Before using this door operator you should first thoroughly read this manual and keep for future reference ...

Page 2: ...imer Door closing speed Slow close distance Direction of door opening 4 Test button switch The test button switch White for door opening and closing is provided on the microcomputer control box The hold timer door opening and closing speed are easily checked with this switch 5 Various functions There are a variety of extra functions that are available on the microcomputer that are not supplied for...

Page 3: ...e speed 20mm sec Speed is fixed after slowing down Brake position Automatically set according to door weight Slow speed distance Position 0 55mm from close where door speed starts to slow Position is adjustable on controller Hold time Time door is held open Adjustable between 0 10sec on controller Door opening width Adjustable to 10 100 as an extra function CS supply as 100 adjustability is additi...

Page 4: ...4 3 WIRING 1 Example wiring Optional parts are marked with ...

Page 5: ...en the door 4 Advanced Features Optional upon order The following advanced features can be applied to the auto door unit upon request The wire loom L003 will need to be ordered from CS FOR DOORS to be able to wire connect the activation devices to the controller OUTPUT 24VAC 0 5A 24V AC is supplied from this output for an auxiliary device requiring power Terminal A and H on advanced input plug A i...

Page 6: ...ng before the door starts to close This only applies when the activate switch sensor etc turns OFF otherwise the door will stay open The hold open time is adjustable from 0 to 10 seconds on the front of the controller 2 CLOSING SPEED mm S The speed the door closes is adjustable on the controller through the potentiometer on the front The closing speed can be set to 100 500mm sec The speed is set a...

Page 7: ...andard Position L If the power is turned OFF again wait for about 5 seconds before turning ON again DOOR HANDING 5 TEST BUTTON The test button allows you to open and close the door without an activation switch This allows controller functionality to be checked while accessing the controller without an activation switch This button also resets the digital counter for door opening and closing See do...

Page 8: ...r M005 9 4PIN FEMALE CONNECTION Connection point for the 4pin male connector plug from the optional motor lock LK01 10 DIP SWITCH Adjustable dip switches on top of controller See document section DIP SWITCH FUNCTIONS for more details 11 ACCESSORY SCREWDRIVER All adjustments of hold open timer closing speed slow close distance opening direction are done using this screwdriver Adjustments using othe...

Page 9: ...s learning the open and closed positions of the door 3 Adjusting the settings for hold open timer closing speed and slow close distance Setting information for opening closing times when door is fully closed are displayed on the LED monitor When adjusting the hold time 0 10sec HLd Hold time is variable every 0 5 sec between 0 to 10 seconds on adjustment screw pot 10 500 100 10 500 100 0 10 100 500...

Page 10: ...ollowing information During opening Opening speed setting 500mm s Adjustable on dip switch Braking on opening Second distance setting 60 When fully closing When opened by activation device Will count down in 0 5 sec increments from present setting 4 sec in image example During closing Closing speed setting 200mm s Braking on closing Second distance setting 60 Displays the number of completed open ...

Page 11: ...ode 200mm sec DIP SWITCH 2 OBSTACLE DETECTION Setting for adjusting the sensitivity of obstacle detection which re opens the door when meeting a person or object The sensitivity for obstacle detection while the door is moving at a set speed can be adjusted to the following State Setting ON UP STANDARD If the set speed is decreased by more than 75 for 0 5 sec the door re opens In closer mode decrea...

Page 12: ...e State Setting ON UP With pressing continuous push to close OFF DOWN No pressing DIP SWITCH 5 DOOR FUNCTION Selection of whether the microcontroller acts as an automatic door operator or a door closer State Setting ON UP AUTODOOR Automatic door operator OFF DOWN CLOSER Door closer DIP SWITCH 6 DIRECTION OF FIRST MOVE The direction of the initial door movement is selectable when the power is turne...

Page 13: ... photo of your setting before attempting to reset the cycle count Remember to remove the power from the controller when adjusting dip switch settings HOW TO RESET THE CYCLE COUNT Turn DIP SWITCH ON UP if the digital counter is to be reset Hold Test Button for 3 seconds Cycle count will reset Door will start a new learning sequence to find open and closed positions If dip switch 6 is OFF Down when ...

Page 14: ...matically locks when the door is in fully closed position The lock is unlocked and the door opens and closes when the activate switch is turned ON 3 Motor Mounts Aluminium casting with rubber inserts fits the motor to the track and allows easy removal of the motor for maintenance Motor removal once belt is removed from motor pulley Disconnect motor and lock connectors from controller Slide motor i...

Page 15: ...egarding screws and wires 5 Move door to the centre of the opening ready to connect the power 2 Initial movement at power ON 1 When power is turned ON the red LED display shows door opening and closing times 2 The door moves according to dip switch 6 3 During the initial movement When activation devices are off The door when fully open starts closing after the pre set hold open period When closed ...

Page 16: ...seconds and reconnect power Motor connector is missing Wire for motor sensor is broken Motor is out of order Motor sensor U is abnormal Motor sensor U has not changed for more than 5 sec during motor operation Remove power Wait 5 seconds and reconnect power Motor connector is missing Motor wire is broken Motor is out of order Motor shaft is locked Normally it does not occur Motor sensor V is abnor...

Reviews: