4.3.5 Normal Operation
Note:
Operate the remote control transmitter as required. Motion control switches are designed to revert to
neutral when released. Any or all functions may be operated simultaneously if the controlled machine
permits such operation.
In normal operation, the STATUS LED (centrally located above the optional LCD screen) flashes green. When the
battery voltage becomes low, the STATUS LED flashes red and a beep sounds every ten seconds to alert the
operator that the battery pack needs to be replaced or recharged.
Only Cattron battery packs should be used; if the battery type is not recognized, the STATUS LED flashes yellow.
The STATUS LED also illuminates in a series of red blinking sequences to indicate a specific OCU fault, as
described in
The OCU switches off automatically when the following events occur:
•
Battery low voltage detected (after a preset time delay)
•
Internal fault detected
•
STOP switch depressed
•
ON/OFF switch pressed
4.4 Changing the Battery
Referring to
, remove the battery pack as follows:
1. Lay the OCU on its side.
2. Remove the rechargeable battery pack from the bottom of the OCU by pressing the battery latch button
and sliding out the battery.