CattronControl™ LRC-S1
User Manual
20
9M02-9124-A001-EN
Version 2.0
7
Technical Data
7.1 Transmitter (OCU)
Frequency bands
Dependant on region:
433-434 MHz (Europe)
902-927 MHz (North America and other applicable countries)
Transfer rate
4.8 - 20 kbps
Transmission power
1-10 mW (within the allowable limits)
Antenna
Internal
System addresses
24 Bit
Power-saving mode
Automatic switch-off (configurable 0 – 30 minutes)
Power supply
Ni-MH, 4.8 V, 1600 mAh, quick-swap rechargeable battery pack
Operating time
>12 h @ 100% duty cycle
Operating elements
2 joysticks
STOP, START, HORN
5 configurable pushbutton switches, each with an associated LED
Indication
1 STATUS/multi-function LED
6 switch status LEDs
LCD display (optional)
Acoustic signal for status/tilt/low battery and error indication
Weight
2.2 lb (1.0 kg) with the battery installed
Dimensions (L x W x H)
9 x 4.6 x 6 in (229 x 117 x 152 mm)
Housing
Lexan EXL Polycarbonate Resin, standard colors: grey/red with black railing
Operating temperature
-4º to 140º F (-20º to +60º C)
Protection class
IP 65
Safety
EN 13849-1 Performance Level d for all safety related functions
EN 60204-1
EN 60204-32
CE Compliant
7.2 Battery Charger
Model
Processor-controlled charger for Ni-MH battery packs
Dimensions (W x D x H)
2.4 x 3.5 x 4.7 in (60 x 90 x 120 mm)
Power supply
Primary: 100 – 240 VAC, 50/60 Hz, 17 VA, 300 mA
Secondary: 1.45 – 14.5 VDC, max. 800 mA, 9.6 VA