Procedure for opening the door:
To open the tilting/pivoting door, the following procedure must be respected:
-
Undo the 2 safety latches located in the upper extremities of the door and leave them in the open
position (figure 25).
-
Proceed to manually open the door, lifting from the outside using the handles.
-
When the door has slid into its final position recessed in the deck head, ensure you engage the
toggle-latches to lock the door in the open position (figure 26).
Procedure for closing the door:
To close the tilting/pivoting door, the following procedure must be respected:
-
Disengage the safety toggle-latch to release the door.
-
Carefully lower the door manually into its closed position.
-
When the door has slid into its final closed position, do up the 2 safety latches located in the upper
extremities of the door, ensuring that the latches have correctly clicked into place (figure 27).
Maintenance:
Unscrew the stainless-steel covers on the aft face of the fixed posts (figure 44) and those on top of the posts
(figure 45).
Carry out a visual check of the general condition of the door and all components. Check the tension of the
cables and the wear of the friction parts.
Oil all friction points with a standard lubricating oil.