24
3.4. Event Setup
In Event Setup, you may designate the Alarm Output
Operation method when a Sensor or Motion Detection
is activated.
Select the Camera/Alarm Link, Alarm operation
Mode, and Output Dwell Time when a Sensor or.
Motion Detection is activated.
CATEGORY
DEFAULT
VALUE
FUNCTION & OPERATION METHOD
SENSOR
•
Select the Sensor number
Click the Sensor number.
TYPE NO
•
Select the Sensor Type
Turn the mouse wheel to select between NO(Normal Open) and
NC(Normal Closed)
CAMERA LINK
•
Assign the Camera that is to be linked to the selected Sensor.
•
The selected Camera will be displayed on the monitor in Full
Screen when the sensor is activated if the FULLSCREEN mode is
selected below.
Click the Camera number or numbers that is to be linked to the
Sensor.
ALARM LINK
•
Assign the Alarm that will activate when the Sensor is triggered.
Click the Alarm that is to be linked to the Sensor.
OPERATION TIME
0~24
•
Set the Time for which the Alarm will operate.
•
Input Range : Between 0~24(Unit : Hour)
Click the time field and turn the mouse wheel to change the
time. Only the hour can be changed.
FULLSCREEN MODE
OFF
•
Select the Monitoring Screen Display type when the Sensor is
triggered.
- OFF : No changes in the monitoring screen.
- ON : For 1:1 Camera and Sensor link, the activated camera
view will appear in single channel Full Screen Display
mode for 5 seconds and the DVR internal buzzer will beep
for 3 seconds.
•
If several Cameras are linked to the Sensor, the single channel
Full Screen mode cannot be applied.
Turn the mouse wheel to select between OFF and ON.
OUTPUT DWELL TIME
0
•
Set the length of time you want the Alarm activated when a
Sensor is activated.
•
Input Range : 0~600 Seconds
Turn the mouse wheel to change the Output Dwell Time.
(Continued)
Configuration