When joining small mouldings, lower than the height of the stops, it is necessary to use the set of
spacer bars supplied with the machine.
The MACH 1 UNI is designed to join mouldings in 1 to 5 places (positions) with a maximum
of 5 wedges in each place (position). The selection depends on the width and thickness of the
moulding to join.
ESSENTIAL & GENERAL RULE :
-A MINIMUM 2 mm clearance (less than 1/8”) above the wedges shall be respected.
-Same size wedges can be stacked in order to avoid to have to change the wedge size when joining
frames with different thickness.
AS A GENERAL RULE, THE JOINING MUST BE CARRIED OUT AS
CLOSE TO THE THICKEST MOULDING PART(S) AS POSSIBLE .
190mm
stroke
2mm MINIMUM
2mm MINIMUM
3.B. SPECIFIC USE OF THE SPACER BARS
3.C. SELECTING THE STAPLING POSITION
GOOD
BAD
Switch on the Pre-Clamp button
14
.
Put in place your mouldings on the table.