Non contractual document - Cassese France
®
- Document non contractuel
- 10 -
2.D. STARTING UP
-Connect the electrical plug of the MACH 1 UNI to a grounded 220V single-phase outlet.
-Pull up the compressed air valve to
ON
. The air pressure gauge should show 6 bars (85 p.s.i.).
If not, correct it with the air pressure regulator knob as explained in the procedure :
2.C. Connecting to the air source.
WHEN YOU SWITCH ON THE MACH 1 UNI :
(thanks to the Switch on the EMERGENCY / STOP & START BUTTON 3)
-The screen displays “Cassese MACH-1” and “FIRMWARE 01.00”.
-If a button is engaged, the screen displays “RELEASE ALL BUTTONS & PEDAL” with the value of
the engaged button(s) until none of the buttons are engaged. It helps to detect potential trouble
before using the machine when you switch on.
-Then, the screen displays “PRESS A BUTTON OR” and “PRESS PEDAL”. It indicates the machine is
not initialized. Press a button or the pedal. The crossbar initializes itself and come back in Position
1.