— 62 —
5-8-7. Laser Scanner movement
No
Operation
Display
Inspection contents
1
Set the supply voltage to
4.0V.
Select [Laser Current] in
the test program.
Backlight is turned off.
Check that the current value is as follows.
- “150 mA” or lower (DT-X100M10 series/
M30 series)
- “250 mA” or lower (DT-X100M50R)
Within spec: Press the “1” key.
Out of spec: Press the “0” key.
Pressing “1” or “0” returns you to the
Menu screen.
5-8-8. 2D Module movement
(For DT-X100M10 series/M30 series only)
No
Operation
Display
Inspection contents
1
Set the supply voltage to
4.0V.
Select [2D Current] in the
test program.
Backlight is turned off.
Check that the current value is 360mA or
lower.
Within spec: Press the “1” key.
Out of spec: Press the “0” key.
Pressing “1” or “0” returns you to the
Menu screen.