— 48 —
5-4-7. Speaker
No
Operation
Display
Test Details
1
Select [Speaker].
The volume changes from small,
medium to large at frequency of 3kHz.
The volume changes from small,
medium to large at frequency of
10kHz.
The sound time for each volume is 0.3
sec. and the sound is repeated for 4
times.
If sound from the speaker is correct: OK
Press the “1” key.
If sound from the speaker is incorrect:
Failure
Press the “0” key.
Pressing “1” or “0” returns you to the
Menu screen.
5-4-8. Vibrator
No
Operation
Display
Test Details
1
Select [Vibrator].
After operating Vibrator for 3 seconds,
the result screen is displayed.
If Vibrator vibrates: OK
Press the “1” key.
If Vibrator do not vibrate: Failure
Press the “0” key.
Pressing “1” or “0” returns you to the
Menu screen.
5-4-9. Charge LED
No
Operation
Display
Test Details
1
Set DT-X100to HA-
F60IO.
(Attention)
Use a battery not fully
charge
Select [Charge LED].
Check that a Charge LED lights in orange
or green.
If LED lights properly: OK
Press the “1” key.
If LED does not light: Failure
Press the “0” key.
Pressing “1” or “0” returns you to the
Menu screen.