5-8-4. Sleep mode
No
Operation
Display
Inspection contents
1
Set the supply voltage to
4.0V.
Select [Sleep mode
Current] in the test
program.
Backlight is turned off.
Check that the current value is as follows.
- “65 mA” or lower
Within spec: Press the “1” key.
Out of spec: Press the “0” key.
Pressing “1” or “0” returns you to the
Menu screen.
5-8-5. Main Dummy Load
No
Operation
Display
Inspection contents
1
Set the supply voltage to
4.0V.
Select [Main Dummy
Load] in the test program.
Check that the current value is as follows.
- “70-100 mA”
Within spec: Press the “1” key.
Out of spec: Press the “0” key.
Pressing “1” or “0” returns you to the
Menu screen.
5-8-6. Power off
No
Operation
Display
Inspection contents
1
Set the supply voltage to
4.0V.
Turn off the DT-X100
power.
Check that the current value is as follows.
- “1 mA” or lower