— 22 —
3. L-CASE-UNIT
* The following explains the procedure after the L-CASE-UNIT has been removed from DT-X100 (Refer to 2-1).
3-1. LASER-MODULE (Laser model)
(1) Peel off the TAPE/CONNECTOR-B and remove the FPC from the connector.
(2) Undo 2 screws and remove the LASER-UNIT from the L-CASE-UNIT.
Screws (S3)
TAPE/CONNECTOR-B
(3) Undo 2 screws and remove the LASER SCANNER from the LASER HOLDER.
(4) Peel off the TAPE/CONNECTOR-A and remove the FPC-PY055VA4-LS.
Screws (S4)
TAPE/CONNECTOR-A
(5) Assemble the removed parts by reversing the disassembly procedure.
Attach the CUSHION/LASER-A and CUSHION/LASER-B to the FPC-PY055VA4-LS. (For the locations,
refer to the picture below.)
Attach the TAPE/CONNECTOR-A so that it covers the connector.
After that, attach the CUSHION/LASER.
TAPE/CONNECTOR-A
CUSHION/LASER-B
CUSHION/LASER
CUSHION/LASER-A