CAS Talline Installation & Operating Instructions Manual Download Page 19

 The Warranty is void under the following circumstances:

Installa on is carried out incorrectly by any person other than a person authorised by us to do so.

The Power Pack or Cell is serviced by any person other than a person authorised by us to do so.

Correct salt levels are not maintained at all  mes.The Power Pack is not protected from the elements.

The Power Pack is not operated in a posi on/area with good ven la on.

Water has been allowed to enter the Power Pack or Junc on Box.

Run in a commercial installa on (these have a 1 year warranty on Power Pack and Cell unless a commercial 

model is purchased then this is 24 months).

Insect infesta on or penetra on by dust, sand or other foreign par cles inside the Power Pack.

Damage beyond our control.

Equipment that has been misused, neglected, damaged, repaired without authorisa on or altered in any 

way.

This warranty is applicable to workmanship and materials only.
This warranty is not transferable under any circumstance.
This unit is for use in domes c swimming pools only where the correct size unit produces enough chlorine in 
approx. 8 hours. Extended periods to gain more chlorine produc on voids the Warranty.
Keep your original purchase invoice and serial number in a safe place.

11. WARRANTY

19

The 

Talline

™ Power Pack will be repaired at no charge for a period of 24 Months from the date of 

purchase  should  it  be  found,  a er  examina

ti

on,  that  the  failure  has  been  caused  by  faulty 

workmanship  or  materials.  This  is  a  back  to  base  warranty.  The  Electroly

ti

c  Cell  carries  a  1  year 

repair  /  replacement  +  4  years  pro-rata  warranty  (based  on  a  percentage  of  the  recommended 
retail price nominated by the manufacturer).
*The warranty applicable to commercial applica on is limited to 12 months from the date of 
installa on unless a commercial model is purchased then this is 24 months. 
Adverse opera ng condi ons beyond the control of the manufacturer such as improper voltage or 
water pressure, excessive ambient temperature or any condi on that adversely affects the 
performance of the equipment will render this warranty null and void.
Defec ve equipment must be returned to the manufacturer or dealer as soon as the purchaser 
becomes aware of the defect and all transport must be prepaid. Neither the manufacturer nor the 
dealer shall be responsible for any goods damaged in transit.
If a er examina on the equipment is found to be defec ve it will be repaired or replaced free of 
charge (other than transport costs which will be borne by the purchaser). However, if upon 
inspec on of the equipment it is found that the terms of this warranty are not sa sfied, then the 
usual charges of the manufacturer for repair or replacement will be made.
Any liability of the manufacturer pursuant to the Trade Prac ces Act 1974, as amended for a breach 
of a condi on or warranty shall be limited to replacing or acquiring the equipment (or part thereof) 
where the same has been supplied.
The maximum liability incurred by the manufacturer shall not in any case exceed the contract price 
for the equipment or the product parts or components thereof claimed to be defec ve. Further, the 
manufacturer shall not be liable for any loss, damage or delay directly or indirectly caused by any 
malfunc on of or defect of or failure of the equipment other than as expressly provided in this 
warranty.
Products sold by the manufacturer are designed for use with swimming pool water balanced in 
accordance with the Langelier Satura on Index with a pH range of 6.8-7.8. Chlorine level should not 
exceed 4ppm and the salt level should not exceed 4000ppm.
The manufacturer will not be held liable for damage caused by, but not limited to, corrosion, scaling 
or stress.

THIS EQUIPMENT HAS BEEN MANUFACTURED AND TESTED TO THE HIGHEST STANDARD 

AND ACCORDINGLY CARRIES THE FOLLOWING WARRANTY.

1

1

.1

1

1

.

2

1

1

.

3

1

1

.4

1

1

.5

1

1

.6

1

1

.7

1

1

.8

Summary of Contents for Talline

Page 1: ...INSTALLATION OPERATING INSTRUCTIONS MODEL TL RANGE s a l t w a t e r c h l o r I n a t o r Talline...

Page 2: ...ctrode Installa on 6 4 3 Installa on Diagram 7 5 Power Pack Opera on 8 5 1 Timer Switch 8 5 2 Cell Switch 8 5 3 Circuit Breaker 8 5 4 AC Socket Pump Outlet 8 5 5 Junc on Box 8 5 6 and Bu ons 8 5 7 Out...

Page 3: ...aller must ensure that the Electroly c Cell is never energised when the pool pump is OFF or water is not owing throughtheunit 1 1 Important Warnings This manual contains important informa on about the...

Page 4: ...s a vital part of a complete maintenance program and will ensure trouble free performance as well as a healthy and sparkling clean pool The Talline range is a reverse polarity model known as TL which...

Page 5: ...We recommend 3 5kg per 1000 litres 1 cubM of pool water and a 50 000 litre 50 cubM new pool needs approximately 175kg of salt The unit can operate on mineral magnesium chloride salts and you should al...

Page 6: ...the controls on the Power Pack 4 2 Cell Electrode Installa on Connect the Cell Housing horizontally in the return line to the pool use reducing bushes supplied if 40mm PVC pipe using high pressure PV...

Page 7: ...he installa on It is RECOMMENDED that the Cell Housing be installed horizontally to create a natural gas trap that acts as a safety device Installa on in any other way may cause explosion injury or de...

Page 8: ...erated electrical switch designed to protect an electrical circuit from damage caused by overcurrent overload or short circuit It can be reset by pressing the bu on in a er it has tripped It may be da...

Page 9: ...ll 8 Output LED s indicate salt levels are correct and if they do not reach 8 then salt levels need to be checked or contact your local Crystal Aquatic Systems agent for assistance 5 11 Start Up Proce...

Page 10: ...ol givingit metodoitswork Winter Se ngs Inwinteryoushouldloweryourrunning mebyupto50 ofyoursummerse ngdependingon your free chlorine levels You should ideally run 2 3 hours in the morning and 2 3 hour...

Page 11: ...s charging at rst but simply leave it alone and it will charge itself as required This me is set at 8 00am and the dial pointer shows the 8 00 posi on as does the clock face hands The Timer comes on w...

Page 12: ...nt salt will damage your Cell The unit will operate with good stability on higher salt levels but it is s ll advisable to run at the correct leveltopreventdamage Saltlevelsabove5000ppmmayoverloadtheun...

Page 13: ...does not become too corrosive or end up scaling the surface of your pool These are symptoms of swimming pool water that is unbalanced 7 6 Stabiliser Measurement Interval Every 4 6 weeks IdealStabilise...

Page 14: ...ds are in sound condi on at least once a year 8 1 Inspec ng and Cleaning the Power Pack Li le or no maintenance is normally required with the Talline Chlorinator Power Pack Ensure the Power Pack 3 pin...

Page 15: ...mmerse the electrode in cell cleaning solu on A solu on can be made by mixing 1 part hydrochloric acid to 10 parts of water If excessive build up is present a stronger solu on may be used to remove th...

Page 16: ...e Bu on 2 If green LED s do not increase 3 Check Cell lead connec on at the Junc on Box repair if damaged or return for service Ensure su cient water ow through Chlorinator Cell Check that the pump is...

Page 17: ...MANUAL for normal running Poten al Cause Remedy Pump not plugged into chlorinator 9 8 Cell not cleaning excessive calcium build up on Cell or Power Pack not changing direc on 1 See Calcium Hardness t...

Page 18: ...55 MODEL VOLTS Vac Input 210 265 210 265 210 265 VOLTS Vdc Output 188 5 318 0 227 5 Frequency Hz Weight kg Dimensions cm AMPS Adc Output 15 0 25 0 17 5 8 89 8 14 8 85 41L x 35W x 19H 41L x 35W x 19H 4...

Page 19: ...24 months Adverse opera ng condi ons beyond the control of the manufacturer such as improper voltage or water pressure excessive ambient temperature or any condi on that adversely a ects the performan...

Page 20: ...da ons in this guide are current free from errors or omissions or appropriate for the user s circumstances or abili es No liability or responsibility is accepted for any loss su ered as a result of an...

Reviews: