17
9.9
Low or No Chlorine Output
Unit not working correctly
Check Salt guide (sec. 7.2)
Check pH guide (sec. 7.3)
Check Stabiliser guide (sec. 7.6)
Go through Troubleshoo ng from 9.2
Basic se ngs such as Output Control and Timer running
hours need to be checked
Poten al Cause
Remedy
9.4
Sign of mel ng or burning of the Junc on Box
The screws were not adequately ghtened during
installa on
If melted then it will need replacing otherwise
ghten as required
Return for service if melted
Poten al Cause
Remedy
9.5
Power Pack only works in one direc on
Faulty
R
ec fiers,
T
ransformer or PCB
Return unit for service
Poten al Cause
Remedy
9.7
Pool pump outlet not func oning properly or pump always on
Check that pump is plugged into the bo om of the
Power Pack and not directly in to the wall outlet
Make sure you are set in AUTO mode and not
MANUAL for normal running
Poten al Cause
Remedy
Pump not plugged into chlorinator
9.8
Cell not cleaning, excessive calcium build up on Cell or Power Pack not changing direc on
1. See Calcium Hardness test (sec. 7.5) and adjust
water accordingly
2. Change the Hard/So Switch to HARD (sec. 5.9)
3. Manually try reverse direc on (sec. 5.2 - Cell
Switch Changing Direc on). Failure for this to work
could indicate a faulty PCB - return for service
Poten al Cause
Remedy
Excessively high calcium, change of direc on me
set too high or faulty PCB
Salt level is to low
pH is too high
Stabiliser is too low
Cell at the ends of its life
Unit not set correctly
9.10
Timer loses me when mains power removed
Ba ery life expired
Replace Timer - return for service
Poten al Cause
Remedy
9.6
Timer is not func oning properly
Make sure Timer Switch is set to AUTO and White
Lever in the centre of Timer is set to me clock
posi on and not "I" or "O"
Refer to Timer Se ng in this manual (sec. 6)
Poten al Cause
Remedy
Incorrect Timer se ngs
9. CHLORINATOR TROUBLESHOOTING