7
3. Technical Specification
■
Analog Part & A/D Conversion
Load Cell Excitation Voltage
DC 9V, 8 x 350
Ω
load cells
Zero Adjustment Range
0.05mV 20mV
∼
Input Sensitivity
1.2
μ
V/D (H-44,OIML)
0.6
μ
V/D (Non H-44,OIML)
System Linearity
Within 0.01
%
of F.S.
A/D Internal Resolution
1 / 200,000
A/D External Resolution
5,000 dd (H-44,OIML)
10,000 dd (Non H-44, OIML)
A/D Conversion Speed
Maximum 50 times/sec
■
Digital Part
Span Calibration
Full Digital Calibration : SPAC
™
(Single automatic span calibration)
Display
VFD (7 digit) : 6.0(W) x 13.0(H) mm
Sub Display
(NT-505A)
VFD (12 digit) : 3.3(W) x 8.0(H) mm
Division
×1, ×2, ×5
Display Below Zero
Minus
Tare Subtraction
Full capacity
“ST”(Stable)
▼
LAMP
Weight is stable
“HIGH”
▼
LAMP
Displays on/off status of high limit relay –
Except NT-501A
“LOW”
▼
LAMP
Displays on/off status of low limit relay –
Except NT-501A
“HOLD”
▼
LAMP
Hold function is activated
“NET”
▼
LAMP
ON(net weight), OFF(gross weight)
“TARE”
▼
LAMP
Tare is activated
“ZERO”
▼
LAMP
Current weight is “0” kg