35
F22
FUNCTION : Data transmission
VF DISPLAY
SUB DISPLAY
DESCRIPTION
0
No data transmission
1
Transmit data in a state of stable &
unstable
2
Transmit data only in stable state
3
Transmit data only in command mode
4
Transmit data if you press PRINT
key(PRT)
Set value
(0 ~ 4)
5
F22 SENd
Transmit data if you input Device ID
Note 1. The default value is set to 0 at factory.
Note 2. If F30 is set to 4, do not transmit weight data.
Note 3. When F22 is set to 3,( Refer to 3) Command mode at page 16.
Note 4. When F22 is set to 5. The device ID is the data demanding signal in seria
Communication
EX>
Device ID
Input Signal
03 03
10 0A
F23
FUNCTION : Device ID (Identification of each indicator)
VF DISPLAY
SUB DISPLAY
DESCRIPTION
00
Device No. 00
Set value
(00 ~ 99)
05
F23 dEVICE
Device No. 05