174
APPENDIX E — UPC OPEN CONTROLLER (cont)
Table D — Open System Wiring Specifications and Recommended Vendors
LEGEND
Local access to the UPC Open —
The user can
use a BACview
6
handheld keypad display unit or the Virtual
BACview software as a local user interface to an Open control-
ler. These items let the user access the controller network infor-
mation. These are accessory items and do not come with the
UPC Open controller.
The BACview
6
unit connects to the local access port on the
UPC Open controller. See Fig. F. The BACview software must
be running on a laptop computer that is connected to the local
access port on the UPC Open controller. The laptop will re-
quire an additional USB link cable for connection.
See the
BACview Installation and User Guide
for instruc-
tions on connecting and using the BACview
6
device.
To order a BACview
6
Handheld (BV6H), consult Commer-
cial Products i-Vu Open Control System Master Prices.
WIRING SPECIFICATIONS
RECOMMENDED VENDORS AND PART NUMBERS
Wire Type
Description
Connect Air
International
Belden
RMCORP
Contractors
Wire and Cable
MS/TP
Network (RS-485)
22 AWG, single twisted shielded pair, low capacitance, CL2P,
TC foam FEP, plenum rated. See MS/TP Installation Guide for
specifications.
W221P-22227
—
25160PV
CLP0520LC
24 AWG, single twisted shielded pair, low capacitance, CL2P,
TC foam FEP, plenum rated. See MS/TP Installation Guide
for specifications.
W241P-2000F
82841
25120-OR
—
Rnet
4 conductor, unshielded, CMP, 18 AWG, plenum rated.
W184C-2099BLB
6302UE
21450
CLP0442
AWG
—
American Wire Gage
CL2P
—
Class 2 Plenum Cable
CMP
—
Communications Plenum Rated
FEP
—
Fluorinated Ethylene Polymer
TC
—
Tinned Copper
Fig. F — BACview
6
Device Connection
a48-8583
Summary of Contents for WEATHERMAKER 48/50AJ
Page 103: ...103 Fig 15 Typical Main Control Box Wiring Schematic 48 50AJ AK AW AY Units cont a48 8355 ...
Page 104: ...104 Fig 16 Typical Main Control Box Wiring Schematic 48 50A2 A3 A4 A5 Units a48 8355 ...
Page 105: ...105 TO NEXT PAGE Fig 17 Typical Auxiliary Control Box Wiring Schematic A48 7294 ...
Page 106: ...106 Fig 17 Typical Auxiliary Control Box Wiring Schematic cont a48 8356 ...
Page 107: ...107 Fig 18 Typical 2 Stage Gas Heat Wiring Schematic Size 051 and 060 Units Shown a48 8357 ...
Page 113: ...113 Fig 22 Typical Power Schematic 48 50A2 A3 A4 A5060 Unit Shown ...
Page 114: ...114 SW1 SW2 OR DEHUMIDIFY SWITCH Fig 23 Typical Controls Option Wiring Schematic a48 8361 ...
Page 115: ...115 Fig 24 Typical Small Chassis Component Location Size 020 035 Units a48 8362 ...
Page 116: ...116 Fig 25 Typical Large Chassis Component Locations Size 036 060 Units A48 7302 ...
Page 169: ...169 APPENDIX C VFD INFORMATION cont Fig F Internal Enclosure Fan Replacement A48 7716 ...