11
MENU
Leg
end
*
Displa
y
ed if the configur
ation requires it
**
Displa
y
ed if the alar
m e
xists
-
Not in use
ITEM
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
ST
A
TUS
Def
ault displa
y
Modes
Occupied/
unoccupied
mode*
Min
utes left
Cooling/heating
status*
Compressor
capacity in %
Additional
heating in %*
Demand limit
status
Setpoint
Activ
e setpoint
Control point
Control dead
band
Room
temper
ature
Economiser
status*
-
-
-
-
-
-
TEMP
Room temperature
1
Supply air
temperature
Outdoor
temperature
Saturated discharge
temp
. circuit A
Saturated suction
temp
. circuit A
Saturated discharge
temp. circuit B*
Saturated suction
temp. circuit B*
Defrost tempera-
ture
, circuit A*
Defrost tempera-
ture, circuit B*
Offset sensor
T56*
Heating coil leaving
water temperature*
Room temperature
2*
-
-
-
-
-
-
-
-
PRESSURES
Discharge pressure
circuit A
Suction pressure
circuit A
Discharge pressure
circuit B*
Suction pressure
circuit B*
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SETPOINTS
Room temperature
setpoint, occupied
mode
Room temperature
dead band,
occupied mode
Room temperature
setpoint, unoccu-
pied mode
Room temperature
dead band,
unoccupied mode
Frost protection
setpoint
Cooling mode -
outside temperature
for z
ero offset*
Cooling mode -
outside temperature
for max.
offset*
Cooling - full offset
value*
Setpoint room
humidity
, occupied
mode*
Dead band room
humidity
, occupied
mode*
Setpoint room
humidity
, unoccu-
pied mode*
Dead band room
humidity
, unoccu-
pied mode*
Purge - minimum
outside temp.*
Purge - maximum
outside temp.*
Purge - duration*
Setpoint, air
quality*
-
-
-
-
INPUTS
Indoor fan status
additional
heating stage
status*
Fire detection
contact
Pressure switch
fault contact
-
Contact 1:
on/off*
Contact 2: demand
limit*
Contact 3: setpoint
selection*
Contact 4: setpoint
selection*
Relative humidity in
%*
Air quality in ppm*
Thermostat contact:
G*
Thermostat contact:
y1_w2*
Thermostat contact:
y_y2*
Thermostat contact:
w_w1*
Thermostat contact:
o_w2*
-
-
-
OUTPUTS
Compressor status
Indoor fan status
Outdoor fan status
circuit A*
Outdoor fan status
circuit B*
Additional heating
stage status*
Reversible valve
status*
Outdoor coil heater
status*
Po
w
er e
xhaust
status*
Anti-fire damper
status*
Humidifier status*
Alarm status circuits
A and B
Economiser
position*
Speed, f
an A in %*
Speed, fan B in %*
Hot water valve
position in %*
Local interface test
-
-
-
-
CONFIG
SUB-MENU: User
Configuration (USEr)
SUB-MENU:
Service Configuration
(SErviCE)
SUB-MENU:
Factory Configuration
(F
A
CtorY)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ALARMS
Number of active
alarms/resets**
Active alarm code 1**
Active alarm code 2**
Active alarm code 3**
Active alarm code 4**
Active alarm code 5**
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Menu tree structure
ALARMS HIST
Historic alarm code
1**
Historic alarm code
2**
Historic alarm
code 3**
Historic alarm code
4**
Historic alarm code
5**
Historic alarm code
6**
Historic alarm code
7**
Historic alarm code
8**
Historic alarm code
9**
Historic alarm code
10**
-
-
-
-
-
-
-
-
-
-
RUNTIMES
SUB-MENU:
Runtimes
SUB-MENU:
Maintenance
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-