3

2. Disconnect the connector harness from gas valve.

Disconnect wires from Hot Surface Igniter (HSI) and Flame

Sensor. Disconnect the two wires from the Low Gas

Pressure Switch (LGPS) located on the gas valve.

3. Support the manifold and remove the four (4) screws that

secure the manifold assembly to the burner box and set

aside.

4. Note the location of the green/yellow wire ground wire for

re

assembly later. See 

Figure 2

.

5. Slide one

piece burner assembly out of slots on sides of

burner box.

6. Remove the flame sensor from the burner assembly. See

Figure 3

.

7. Remove the orifices from the manifold and discard.

Figure 2

Manifold Assembly

Orifice

Connect Green/Yellow
ground wire here

Manifold

Gas Valve

Gas valve must be installed on
manifold with minimum engagement of
6 threads. Cross threading is not
acceptable.

Indicated surfaces
to be 90 ˚+ or -2˚

CL

Gas valve is parallel to manifold
    or - 3˚

A11407

Figure 3

Burner Assembly

FLAME SENSOR
(BELOW BURNER)

FLAME ROLLOUT
SWITCH

BRACKET, IGNITER

IGNITER

BURNER SUPT. ASSY

BURNER ASSY

A11403

ORIFICE SELECTION/DERATE

!

CAUTION

UNIT DAMAGE HAZARD

Failure to follow this caution may result in unit damage.
DO NOT re

drill burner orifices. Improper drilling may result in

burrs, out

of

round holes, etc. Obtain new orifices if orifice size

must be changed. (See 

Figure 4

)

Figure 4

Burner Orifice

BURNER 
ORIFICE

BURNER 
ORIFICE

A96249

Determine natural gas orifice size and manifold pressure for

correct input at installed altitude by using 

Table 3

.

1. Obtain yearly heat

value average (at installed altitude) for

local gas supply.

2. Obtain yearly specific

gravity average for local gas supply.

3. Find installation altitude in 

Table 3

.

For Canada altitudes of 2000 to 4500 ft., use U.S.A. Altitudes of
2001 to 3000 ft. in 

Table 3

.

4. Find closest natural gas heat value and specific gravity in

Table 3

.

5. Follow heat

value line and specific

gravity line to point of

intersection to find orifice size and manifold pressure

settings.

Furnace gas input rate on furnace rating plate is for installations

at altitudes up to 2000 ft. (610 M).

In the U.S.A

.; the input rating for altitudes above 2000 ft. (610 M)

must be reduced by 2 percent for each 1000 ft. (305 M) above

sea level.

In Canada

, the input rating must be derated by 5 percent for

altitudes of 2000 ft. to 4500 ft. (610 M to 1372 M) above sea

level.
The Conversion Kit Rating Plate accounts for high altitude

derate.

INSTALL ORIFICES

1. Install main burner orifices. DO NOT use Teflon tape.

Finger

tighten orifices at least one full turn to prevent

cross

threading, then tighten with wrench.

2. There are enough orifices in each kit for largest furnace.

Discard extra orifices.

DO NOT reinstall the manifold at this time.

REMOVE MIXER SCREWS FROM THE

BURNERS

Each burner contains a mixer screw that must be removed. Refer

to 

Figure 5

 for the mixer screw location.

1. Remove the mixer screws from the burners.

It is not necessary to plug the hole in the burner when the mixer

screws are removed.

Figure 5

Mixer Screw Location

A11501

1.9”

(48.76 mm)

1.8”

(46.96 mm)

Location of mixer screw
that must be removed

REINSTALL BURNER ASSEMBLY

To reinstall burner assembly:

1. Attach flame sensor to burner assembly.
2. Insert one-piece burner in slot on sides of burner box and

slide burner back in place.

3. Reattach HSI wires to HSI.
4. Verify igniter to burner alignment. See 

Figure 6

  &

Figure 7

.

Summary of Contents for KGBPN42011SP

Page 1: ...n perform basic maintenance functions such as cleaning and replacing air filters Trained service personnel must perform all other operations When working on heating equipment observe precautions in th...

Page 2: ...ZW037 1 VALVE CVRSN KIT W R SPRING 92 0935 323267 701 1 PARTS ASSY 42 323267 702 1 PARTS ASSY 43 323267 703 1 PARTS ASSY 44 323267 704 1 PARTS ASSY 45 339851 701 1 LABEL KIT 339851 702 1 LABEL KIT 319...

Page 3: ...in yearly specific gravity average for local gas supply 3 Find installation altitude in Table 3 For Canada altitudes of 2000 to 4500 ft use U S A Altitudes of 2001 to 3000 ft in Table 3 4 Find closest...

Page 4: ...43 3 7 43 3 8 42 3 2 850 44 3 8 43 3 5 43 3 6 43 3 7 875 44 3 6 44 3 7 43 3 4 43 3 5 4000 900 44 3 4 44 3 5 44 3 7 44 3 8 1219 925 44 3 2 44 3 4 44 3 5 44 3 6 950 44 3 1 44 3 2 44 3 3 44 3 4 750 42 3...

Page 5: ...625 43 3 7 42 3 2 42 3 3 42 3 4 650 43 3 5 43 3 6 43 3 7 43 3 8 675 44 3 7 44 3 8 43 3 4 43 3 5 10000 700 44 3 4 44 3 5 44 3 7 44 3 8 3048 725 44 3 2 44 3 3 44 3 4 44 3 5 Orifice numbers shown in BOLD...

Page 6: ...stment screw 5 Remove the Propane regulator spring white 6 Install the natural gas regulator spring silver 7 Install the regulator adjustment screw 8 Turn the adjusting screw clockwise in 8 5 full tur...

Page 7: ...its splice connection with the yellow wire of the furnace wire harness Disconnect and discard this orange wire and the splice connection c Connect the yellow wire of the furnace wire harness see b abo...

Page 8: ...3 For Canada altitudes of 2000 to 4500 ft use U S A Altitudes of 2001 to 3000 ft in Table 3 4 Find closest natural gas heat value and specific gravity in Table 3 5 Follow heat value line and specific...

Page 9: ...tion instructions Figure 12 Conversion Rating Plate Label A13070 LABEL APPLICATION 1 Fill in Conversion Responsibility Label 339851 205 and apply over Propane Conversion Responsibility Label Date name...

Page 10: ...amage Improper installation adjustment alteration service maintenance or use can cause carbon monoxide poisoning explosion fire electrical shock or other conditions which could result in personal inju...

Page 11: ...fore installing modifying or servicing system main electrical disconnect switch must be in the OFF position and install a lockout tag There may be more than one disconnect switch Lock out and tag swit...

Page 12: ...er burner Low NOx models in downflow or horizontal positions must use Table 6 21 000 Btuh per burner See input listed on rating plate Use Table 5 22 000 Btuh per burner for models 58DLA 58PHA 58PHB 58...

Page 13: ...44 3 4 44 3 5 43 3 2 U S A 2001 to 3000 610 to 914 800 42 3 4 42 3 5 42 3 6 42 3 7 825 42 3 2 42 3 3 42 3 4 42 3 5 850 43 3 7 43 3 8 42 3 2 42 3 3 875 43 3 5 43 3 6 43 3 7 43 3 8 900 43 3 3 43 3 4 43...

Page 14: ...25 43 2 9 43 3 0 43 3 1 43 3 2 750 43 2 7 43 2 8 43 2 9 43 3 0 775 43 2 6 43 2 7 43 2 7 43 2 8 800 43 2 4 43 2 5 43 2 6 43 2 7 825 43 2 3 43 2 3 43 2 4 43 2 5 850 43 2 1 43 2 2 43 2 3 43 2 4 U S A 700...

Page 15: ...4 43 3 5 900 43 3 0 43 3 1 43 3 2 43 3 3 925 43 2 8 43 2 9 43 3 0 43 3 1 950 43 2 7 43 2 8 43 2 9 43 2 9 975 43 2 5 43 2 6 43 2 7 43 2 8 1000 43 2 4 43 2 5 43 2 6 43 2 7 U S A 3001 to 4000 914 to 1219...

Page 16: ...8 43 2 9 650 43 2 5 43 2 5 43 2 6 43 2 7 675 43 2 3 43 2 4 43 2 4 43 2 5 700 43 2 1 43 2 2 43 2 3 43 2 3 725 48 3 7 43 2 0 43 2 1 43 2 2 750 48 3 5 48 3 6 48 3 7 43 2 0 U S A 9001 to 10 000 2743 to 3...

Page 17: ...itch Lock out and tag switch with a suitable warning label Verify proper operation after servicing For J and G valves See Figure 24 1 Be sure gas and electrical supplies to furnace are off 2 Remove ca...

Page 18: ...re than one disconnect switch Lock out and tag switch with a suitable warning label Verify proper operation after servicing 1 Be sure main gas and electric supplies to furnace are off 2 Remove Low Gas...

Page 19: ...ressure tap on gas valve 2 Turn on furnace power supply 3 Turn gas supply manual shutoff valve to ON position 4 Turn furnace gas valve switch to ON position 5 Jumper R W thermostat connections on cont...

Page 20: ...ition 7 Jumper R and W thermostat connections to call for heat See Figure 13 8 Check manifold orifices for gas leaks when main burners ignite 9 Adjust gas manifold pressure Refer to Table 5 or Table 6...

Reviews: