background image

R-3159

7/01

Page 1

R-3159

INSTALLATION INSTRUCTIONS  

REAR OUTLET, KIT NUMBER ROK-1

MODELS 

FAW-40SPP AND FAW-40IP VENTED WALL FURNACES

Empire Comfort Systems, Inc.  Nine Eighteen Freeburg Ave.   Belleville, Illinois  62222-0529    

INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION

Installing Optional Rear Outlet

Rear outlet kit, 10" boot assembly with register, ROK-1 for warm 

air discharge into an adjoining room.
Attention:  Before furnace is attached to the wall, the wall opening 

for the rear outlet must be cut, in addition to removal of the outer 

and inner casing knockouts on furnace.
  1.  The wall opening measurements for the rear outlet are the fol-

lowing.

A.  From floor to bottom of wall opening is 10 11/16".

B.  From bottom of wall opening to top of wall opening is 8 

1/2".

C.  Wall opening width is 12 1/8".

  2.  Scribe a line between the four dimples on the outer casing back 

to form a square. Drill a pilot hole within the scribed square 

on the outer casing back. Remove the sheet metal within the 

scribed square with a tin snips or comparable tool.

  3.  Remove the (4) #8 x 3/8"  screws that attach the inner casing 

close off plate to the inner casing.

  4.  Insert the privacy shield through the outer casing back and the 

inner casing back. The privacy shield will be in front of the 

inner casing back and behind the combustion chamber tubes. 

Align clearance holes on privacy shield with screw holes on 

inner casing back. Attach privacy shield to inner casing back 

with (2) #8 x 3/8" screws provided.  Attention: The (2) #8 x 

3/8"  screws must be inserted from the front of the furnace.

  5.  Attach furnace to wall (refer to Installation Instructions and 

Owner's Manual).

  6.  Align clearance holes on 8" x 12" boot with screw holes on 

outer casing back and mark boot to be flush with wall surface.  

Remove boot and cut to proper length. 

  7.  Attach  8" x 12" boot to outer casing back with (6)  #8 x 3/8"  

screws provided.

  8.  Align clearance holes on 6" x 10" duct with screw holes on 

inner casing back and mark duct to be 2 1/4" shorter than 8" x 

12" boot.  Remove duct and cut to proper length.

  9.  Attach  6" x 10" duct to inner casing back with (4) #8 x 3/8"  

screws removed in Step 3, 2 on top and 2 on bottom. 

 10.  Insert rear register into 8" x 12" boot.  Attach rear register to 

wall with (2) #10 x 1" screws provided.

 11.  Installation of ROK-1 is completed.

 

 

Summary of Contents for ROK-1

Page 1: ...parable tool 3 Remove the 4 8 x 3 8 screws that attach the inner casing close off plate to the inner casing 4 Insert the privacy shield through the outer casing back and the inner casing back The privacy shield will be in front of the inner casing back and behind the combustion chamber tubes Align clearance holes on privacy shield with screw holes on inner casing back Attach privacy shield to inne...

Page 2: ...wall opening to top of wall opening is 8 1 2 C Wall opening width is 12 1 8 2 Remove outer casing knockout from outer casing back 3 Remove inner casing knockout from inner casing 4 Attach furnace to wall Refer to Installation Instructions and Owner s Manual 5 Align clearance holes on 8 x 12 boot with screw holes on outer casing back and mark boot to be flush with wall surface Remove boot and cut to...

Page 3: ... plaque de fermeture de la paroi intérieure à la paroi intérieure 4 Insérerl écranprotecteuràtraverslaparoiextérieurearrièreetlaparoi intérieure arrière L écran protecteur sera devant la paroi intérieure arrière et derrière les tuyaux de la chambre de combustion Aligner les trous libres de l écran protecteur avec les trous de vis de la paroi intérieure arrière Attacher l écran protecteur à la paro...

Page 4: ...défonçable qui se trouve sur la paroi intérieure 4 Fixer le radiateur au mur Référez vous aux Instructions pour l Installation et Manuel du Propriétaire 5 Aligner les trous libres du trémie de 8 x 12 203mm x 305mm avec les trous de vis de la paroi extérieure arrière et marquer le trémie de façon à ce qu il soit au niveau avec le mur Enlever le trémie et couper à la marque 6 Fixer le trémie de 8 x ...