Each detector communicates electronically over a serial data link via the engine mounted Junction Box
with the Control Panel designed to be mounted within the Engine Control Room. This eliminates the need
to enter the machinery space in alarm conditions.
Control Panel
Auxillary Engine 5 Cylinder
Main Engine 7 Cylinder
Auxillary Engine 5 Cylinder
Junction Box
Junction Box
Junction Box
Engine Room
Control Room
Backup alarm relay
Backup alarm relay
Backup alarm relay
Figure 4
Typical System Configuration
1.3
TECHNICAL SPECIFICATION
Detector
Mounting
¾
inch BSP
Enclosure Rating
IP65
Address Switch
2 x 10 position (0 to 99)
Material
Sample Tube Carbon Loaded PTFE
Detector Black Du Pont Nylon 70G33L
Indicators
Green
Detector On
Red
Alarm
Amber
Detector Fault
Power Consumption
2.8W
Operating Temperature Rating 0 to 70
o
C
Storage Temperature Rating
-20
o
C to 60
o
C
Height
175mm
Width
90mm
Length
205mm
Weight
0.6kg
Summary of Contents for Graviner Mk6
Page 16: ...Nov 21 Page 16 of 132 59812 K001 Rev 10 Height 309mm Width 559mm Depth 118 5mm Weight 8 7kg ...
Page 26: ...Nov 21 Page 26 of 132 59812 K001 Rev 10 Figure 9 Junction Box Installation ...
Page 29: ...Nov 21 Page 29 of 132 59812 K001 Rev 10 Figure 12 Detector Head Installation ...
Page 46: ...Nov 21 Page 46 of 132 59812 K001 Rev 10 Figure 36 System Drawing ...
Page 47: ...Nov 21 Page 47 of 132 59812 K001 Rev 10 Figure 37 Wiring Diagram ...
Page 112: ...Nov 21 Page 112 of 132 59812 K001 Rev 10 6 6 1 CONTROL PANEL Figure 158 Control Panel Door ...
Page 123: ...Nov 21 Page 123 of 132 59812 K001 Rev 10 ...
Page 126: ...Nov 21 Page 126 of 132 59812 K001 Rev 10 ...