Nov-21
Page 53 of 132
59812-K001 Rev 10
2.
Enter engine description letter by letter using the
▲
/
▼
keys to sequence through the alphabet
and the
◄
/
►
keys to move to the next letter Press
store the name. Press
←
to return to
engine description page and select NEXT ENGINE.
Figure 46
Entering Engine Description
3.
Repeat this section to name all configured engines.
2.8.4
Setting Time and Date
Configuration Menu, Figure 42
Figure 47
Set Time & Date
Use numeric keys to set the Time and Date.
2.8.5
Setting Alarm Levels
The system is supplied with default alarm settings for both average and deviation alarms. These
are based on past experience and allow the system to operate initially and gather data from the
engines being monitored. The default alarm values and the allowable range are detailed below.
Alarm Type
Default Settings
Range
Deviation
0.3 mg/I
0.05 to 0.5 mg/I
Average
0.7 mg/I
0.3 to 1.3 mg/I
Back-up
1.6 mg/l
Fixed
Prior to taking oil mist level measurements the Detector temperatures should be allowed to
stabilize to the engine room temperature, this may take approximately 20 minutes.
To enable the alarm settings to be matched to the individual engines, the actual oil mist density
readings should be taken from each engine after it has been operating at full load and reached
maximum operating temperature. This could take up to 2 hours.
Prior to operating the engine all stored oil mist levels must be cleared.
1.
The test readings for the Detectors should be cleared. This is done via MAIN MENU:
ENGINEER 1. Configure System 8. Clr Peak & Avg
Summary of Contents for Graviner Mk6
Page 16: ...Nov 21 Page 16 of 132 59812 K001 Rev 10 Height 309mm Width 559mm Depth 118 5mm Weight 8 7kg ...
Page 26: ...Nov 21 Page 26 of 132 59812 K001 Rev 10 Figure 9 Junction Box Installation ...
Page 29: ...Nov 21 Page 29 of 132 59812 K001 Rev 10 Figure 12 Detector Head Installation ...
Page 46: ...Nov 21 Page 46 of 132 59812 K001 Rev 10 Figure 36 System Drawing ...
Page 47: ...Nov 21 Page 47 of 132 59812 K001 Rev 10 Figure 37 Wiring Diagram ...
Page 112: ...Nov 21 Page 112 of 132 59812 K001 Rev 10 6 6 1 CONTROL PANEL Figure 158 Control Panel Door ...
Page 123: ...Nov 21 Page 123 of 132 59812 K001 Rev 10 ...
Page 126: ...Nov 21 Page 126 of 132 59812 K001 Rev 10 ...