8
5 .2
Boiler front control
This icon indicates that boiler is in the OFF mode (anti-freeze system active).
If the icon is not present the boiler is in the ON mode.
This icon indicates the status of the boiler.
If ON, boiler is in heating mode, if blinking there is a heating request.
This icon indicates the status of the boiler.
If ON, boiler is in the DHW mode, if blinking there is a domestic hot water request.
DHW pre-heating (only for combi models): indicates that a pre-heating cycle has been activated.
Error: indicates any operating irregularities, together with an error code message.
This icon indicates the servicing operation.
If ON, there is a system servicing operation in progress.
This icon indicates that the system is detecting the presence of a flame.
This icon indicates that the system is detecting the absence of a flame.
Water pressure low: these icons are present when the water pressure is low and needs to be re-
pressureized.
External sensor connected
I
cons
SOME OF THE ICONS SHOWN ON THE
CONTROL DEVICE SCREEN AT THE START-
UP PHASE MIGHT NOT BE AVAILABLE
DURING FUNCTIONNING.
THIS DEPENDS ON YOUR BOILER
CONFIGURATIONS
LED
Light signal indicating the operating status of the boiler. Can be as follows
STATUS
RED LED
GREEN LED
RED AND GREEN
Definitive alarm
see “11.16 Lights and faults/Reset procedure”
Transitional alarm
see “11.16 Lights and faults/Reset procedure”
Initial automatic air purge cycle
flashing 0.5 sec on/1.0 sec off
Stand-by
flashing 0.5 sec on/3.5 sec off
Flame presence
ON
Call for Service – Service expire
flashing 0.1 sec on/0.1 sec off
Reset flue hour counter
flashing 0.5 sec on/1.0 sec off
Combustion analysis with flame
ON
DHW
adjustment
left knob
The left knob allows for the domestic hot water setpoint adjustment.
It also allows you to switch from one step to another and change the value of the selected parameter
within the PROGRAMMING menu.
CH
adjustment
right knob
The right knob allows for the central heating setpoint adjustment. The CH setpoint is displayed while
turning the CH knob.
It also allows you to switch from one step to another and change the value of the selected parameter
within the PROGRAMMING menu.
MODE/OK
left button
MODE/OK (left) button allows you to change the BOILER STATUS. You can also:
- navigate through the INFO menu
- select parameters inside the PROGRAMMING menu and confirm the setting of the corresponding
parameter value
MENU/
RESET
right button
MENU/RESET (right) button allows you to reset the boiler and enter in the INFO and PROGRAMMING
menu. You can also:
- exit from the INFO and PROGRAMMING menu
- reset some error codes
D
Isplay
136°F
l
eD
CH
adjustment knob
DHW
adjustment knob