45
AKM0x
X17
X14
1
1
X12
X23
X16
X2
X21
X8
X13
X19
X9
X25
X11
X18
X22
1
1
1
1
1
1
1
1
6
1
5
12
10
4
3
5
4
6
5
6
X15
X1
X4
X6
1
3
1
5
1
2
1
6
X3
X7
arancione
E.R.
F2=4A T
CN1
X10
A9
SW1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1718 19 20
- A B + TA TBOL TBT SE OT+ SBOL X1
X2
9 10
7 8
5 6
1 2
141516 17
nero (RT)
nero (RT)
rosa (OT+)
rosa (OT+)
arancione (ES)
arancione (ES)
6
1
1
2
5
1
rosso (+)
giallo (B)
arancione (A)
nero (-)
giallo (B)
nero (-)
rosso (+)
arancione (A)
bianco (TBT)
bianco (TBT)
(OT+)
(ES)
(TBT)
(RT)
+
-
A
B
REC
X11
X14
X25
M20
Utilizzare contatto privo di tensione
Voltage free contact input
X1
2
1
3
5
4
rosa
blu
P
N L
F= 3.15A F
230 V
M3
F
blu
marrone
marrone
marrone (+)
blu (-)
PWM
marrone
blu
marrone
blu
VALVOLA GAS
1 2
4
3
OPE
OPE
1
3
X8
M4
230 V
ausiliario
blu
marrone
marrone
6
3
1
2
4
5
blu
TSC2
blu
EA
marrone
giallo/verde
N
F
X6
3
1
2
marrone
X15
blu
V Hv
1
2
rosso (+)
blu (HS)
rosa (PWM)
grigio (-)
X13
V Lv
1
4
bianco bianco
S.M.
-t°
-t°
S.R.
rosso
rosso
-t°
S.F.
grigio
grigio
giallo
T.L.A.
blu
blu
1
12
giallo
X9
Non
usato
1
4
2 3
1
4
2 3
verde A1)
rosso (A2)
rosso (A2)
verde A1)
arancione (K2)
arancione (K2)
bianco(K1)
bianco(K1)
X10
J1
BE20
4
3
2
1
5
rosso blu viola bianco
3V
X12
grigio grigio
viola
viola
rosso rosso
nero (alim.)
blu (sign.)
marrone (-)
S.S.
MOD
T.P.
1
3
1
X19
10
F.L.
C.S.A.
marrone
blu
5
3
1
2
4
X4
combustion analysis
button SW1
- After the “Start-up phase”, “WAIT COMM.” will always
appear, which means that the SC07 front control is waiting
for communication with the boiler. After which, the “Operation
phase” starts: in this phase it is possible to perform all the
supported actions (with the exception of language selection).
The controller stays in the “Operation mode” for 60 seconds
starting from the last time a knob was rotated or a key was
pressed. After 60 seconds has expired, the controller goes into
a “Stand-by” mode, back-light OFF. If there is a knob rotation or
a button pressed the device goes back to the “Operation mode”,
back-light ON, for a period of 60 seconds.
11 .6
First commissioning
- P
ower electrically
the boiler by turning the main power
switch to
“ON”. Plug the boiler into a wall outlet.
- set the status of the boiler to OFF
-
a
ccess the technical parameter
menu
as explained in section “11.11
Access to the PARAMETER menu” page 47
- navigate through the menu by rotating one of the two knobs:
clockwise or counter-clockwise.
CAL.
Select the FORCE AUTO CAL parameter and confirm by pressing
the “MODE/OK” button.
CAL.
The display shows the current value , to modify it, rotate one of the
knobs and set the value to 2 (enabled with offset resetted).
FORCE AUTO CAL function starts and the display shows the icon
“ “. When the icon disappears the function is finished.
After that:
- power on the boiler
- open the gas tap to allow fuel to flow.
- Adjust the room thermostat to the desired temperature (~72°F/
22°C) or, if the system is equipped with a programmable
thermostat, set the occupancy temperature to the desired
temperature. Ensure that the thermostat is “active” and set
correctly (~72°F/ 22°C)
- Then press the “MODE/OK” button repeatedly to select CH or
CH/DHW mode
*****
- Display firmware version: e. g. FW0.1 (no actions are required)
FWX.Y
- Set language (“ENG”=Us, “FRA”=French). Rotate one of the two
dials to choose the preferred language (“ENG” default)
- Press the “MODE/OK” button in order to confirm. If the “MODE/
OK” button is not pressed, the default language is left set up.
ENG
ENG
AIR PURGING FUNCTION
NOTICE:
Each time the boiler is started up an automatic air
purging cycle is carried out; lasting 4 min. When the air purging
is in progress, all heat requests are inhibited and the sliding “AIR
PURG.” message appears.
AIR P
NOTICE:
The air purging cycle can be interrupted beforehand by
removing the cap from the control board cover and pressing the
combustion analysis button SW1 or by pressing the MODE button
for at least 5 seconds.