background image

ACA

SERIES

4

MODES — 

The air conditioner can be set to four 

different modes: Cool, Auto Cool, Energy Saver, Sleep, 
and Fan Only. An LED will light to show what mode 
the air conditioner is in when the button is pressed.
Press the Cool button to enter Cool mode. In Cool 
mode, the unit will run at the selected fan speed to 
maintain the temperature setting.
Press the Energy Saver button to enter Energy Saver 
mode. In Energy Saver mode, after the unit shuts off, 
the fan will continue to run for 3 minutes and then 
shut off until cooling is needed. While the unit is off, 
the fan will cycle on and off. The fan will run for
3 minutes and then go off for 10 minutes. The fan will 
continue to cycle on and off to sample the room tem-
perature until cooling is need again.
Press the Sleep button to enter Sleep mode. In Sleep 
mode, the air conditioner will allow the temperature to 
rise above the temperature setting while you are 
asleep. This feature conserves energy and avoids the 
need to get up during the night and turn off the air 
conditioner. While your body is at rest, there is less 
need for cooling.
Press the Fan Only button to enter Fan Only mode. In 
Fan Only mode, the fan operates to circulate the air in 
the room, but there is no cooling operation. This mode 
is used to circulate the air in the room when cooling is 
not required.
Cooling Modes — With the fan speed button, the air 
conditioner can be set to four different cooling modes 
— Low, Medium, High, or Auto Cool. Hi Cool mode is 
recommended for very warm days or when a fast ini-
tial cooling of the room is desired. Med Cool mode is 
recommended on moderately warm days or when the 
unit has been operating for some time and the temper-
ature is about to reach its desired setting. Lo Cool 
mode is recommended on slightly warm days or after 
the room temperature has reached its desired setting. 
The Auto Cool mode adjusts the fan speed automati-
cally from low to high based on the setting of the ther-
mostat and the actual room temperature.

THERMOSTAT — 

The temperature setting on the 

thermostat can be adjusted from a range of 60 to 90 F 
(16 to 32 C). Press the up and down arrows to change 
the temperature setting. When in Cool mode, the air 
conditioner will start and stop cooling operation in 
order to maintain the temperature setting of the
thermostat.

SLEEP MODE — 

Your Carrier Air Conditioner unit 

can be programmed so that the room temperature is 
allowed to rise while you are asleep. This feature con-
serves energy and avoids the need to get up during the 
night and turn off the air conditioner. While your body 
is at rest, there is less need for cooling.
Press the Sleep button to start Sleep mode. The control 
will allow the temperature to rise 2 F above the tem-
perature setting in the next 30 minutes. It will again 
allow the temperature to rise 2 F above the tempera-
ture setting in the following 30 minutes. After the 
hour period, the temperature setting will not change 
again (for a maximum increase of 4 F above the

setting). This new temperature setting is maintained 
for 7 hours and then sleep mode is ended.
Sleep mode can be cancelled at any time by pressing 
the Sleep button, ON/OFF, Fan Only, or the up and 
down arrow buttons.

DELAYED START TIME — 

The AUTO TIMER 

Hours button (TIMER on remote control) allows you to 
set the air conditioner to turn on after a certain num-
ber of hours. Press the Hours or Timer button to start 
the Delayed Start Time function. A 0.5 will be dis-
played, indicating that there is a 

1

/

2

 hour remaining 

until the machine will automatically turn on. Each 
time you press the Hours or Timer button, another

1

/

2

 hour is added to the on timer until 10 hours is 

reached. After 10 hours, the Delayed Start Time is 
increased by an hour each time the button is pressed. 
The maximum setting is 24 hours.
NOTE: The unit must be off or the Delayed Start Time 
function will not be available.
To cancel the Delayed Start Time function, press the 
On/Off button.

CHECK FILTER — 

The Check Filter function is a 

reminder to the home owner to check the filter for 
cleaning. The Check Filter LED will light after
250 hours of operation. After the filter has been 
cleaned, press the Check Filter button to reset the 
function and the light will go off. The timer cannot be 
reset unless the light is on.

DIRECTIONAL LOUVERS

Directional louvers can be used to control conditioned 
airflow direction. Use the louvers to direct airflow in 
the direction that will provide you the most comfort. 
The louvers can be directed up or down and left or 
right.

ENERGY SAVING TIPS

Your Carrier air conditioner is designed to operate effi-
ciently and save on energy costs. Follow these recom-
mendations for even greater energy savings.
• Select the warmest thermostat setting that will suit 

your comfort needs and leave the thermostat at that 
setting.

• Keep the air filter clean (clean approximately every 

30 days).

• Use drapes, curtains, or shades to keep direct sun-

light from heating the room.

• Do not obstruct the front grille air intake. Do not 

obstruct the top air discharge. Allow air to circulate 
freely around the air conditioner.

• Start your air conditioner before outdoor tempera-

ture, cooking heat, or groups of people make the 
room hot and uncomfortable. This avoids an initial 
period of discomfort while the air conditioner is cool-
ing the room.

• When outdoor temperature is cool enough, use the 

Fan Only setting. This circulates indoor air, pro-
vides comfort, and utilizes less electricity than 
when operating in Cooling mode.

Summary of Contents for 73ACA051T

Page 1: ...___________________________________________________ MODEL CATALOG NUMBER ____________________________________ SERVICE DISCRETE NUMBER __________________________________ SERIAL NUMBER _________________...

Page 2: ...injury to persons when using your air conditioner follow basic precautions including the following Be sure electrical service is adequate for the air con ditioner you have chosen Never use an extensi...

Page 3: ...LS Either the remote control or the control panel on the air conditioner can be used to control the unit The battery cover on the remote control will need to be opened and the tape strip removed befor...

Page 4: ...o start Sleep mode The control will allow the temperature to rise 2 F above the tem perature setting in the next 30 minutes It will again allow the temperature to rise 2 F above the tempera ture setti...

Page 5: ...L The Fresh Air Vent allows the air conditioner to recir culate inside air OFF position draw outside air into the room FRESH AIR position or exhaust room air to the outside VENT position Any position...

Page 6: ...should be replaced The batteries used are AA size batteries CLEAN FRONT GRILLE Be sure to unplug air conditioner before cleaning or removing front grille The front grille may be cleaned after it is r...

Page 7: ...perature Unit air filter is dirty Remove and clean air filter Room was excessively hot when cooling oper ation started Allow sufficient time for unit to cool room Cooling selector set to LO or MED Set...

Page 8: ...be performed during normal working hours All replacement parts whether new or remanufactured assume as their warranty period only the remaining time period for which the applicable component is expres...

Page 9: ..._______________________________ T L PHONE DU PERSONNEL D ENTRETIEN ________________________ NUM RO DE S RIE _______________________________________________ VEUILLEZ CONSERVER UNE COPIE DE VOTRE RE U P...

Page 10: ...Lire les tiquettes du produit pour vous informer de tout indice d inflammabilit ou de toutes autres pr cautions d usage Pour r duire les risques d incendie d lectrocution ou de blessures lors de l uti...

Page 11: ...la minuterie T L COMMANDE ET COMMANDES DU PANNEAU La t l commande ou le panneau de commande du climatiseur peut tre utilis pour contr ler l appareil Ouvrir le couvercle du compartiment de la pile de...

Page 12: ...gr s au dessus du r glage de temp rature dans les prochaines 30 minutes Ceci permettra la temp rature de s lever de nouveau de deux degr s au dessus du r glage de temp rature dans les prochaines 30 mi...

Page 13: ...xterne en position FRESH AIR air frais ou d vacuer de l air vici vers l ext rieur en position VENT ventilation N importe quelle position de r glage du contr le d admission d air frais peut tre utilis...

Page 14: ...la t l commande de la chaleur directe Ne pas renverser des liquides ou placer des objets lourds sur la t l commande S assurer que le signal allant de la t l commande au climatiseur ne soit pas obstru...

Page 15: ...lorsque l op ration de refroidissement a commenc Laisser s couler une p riode de temps suffisante pour permettre l appareil de refroidir la pi ce Le s lecteur de climatisation est la position LO faib...

Page 16: ...ou reconditionn es ne sont couvertes par la garantie que pour la p riode pour laquelle le composant remplac est express ment garanti par la pr sente Les distributeurs ind pendants autoris s ou les po...

Page 17: ...RETO DEL SERVICIO ________________________________ N MERO DE SERIE _______________________________________________ S RVASE GUARDAR UNA COPIA DE SU RECIBO PARA FINES DE LA GARANT A CONTENIDO P gina ALG...

Page 18: ...encias sobre la inflamabilidad y de otra ndole en las etiquetas de los productos Para reducir el riesgo de incendio electrocuci n o lesiones personales al utilizar su aparato de aire acondicionado sig...

Page 19: ...temporizador CONTROL REMOTO Y CONTROLES DEL PANEL Pueden utilizarse el control remoto o el panel de control del aparato de aire acondicionado para controlar la unidad La tapa de la pila en el control...

Page 20: ...ra apagar el aparato de aire acondicionado Mientras su cuerpo descansa hay menos necesidad de enfriar Oprima el bot n SLEEP Hibernar para comenzar el modo hibernar El control permitir que la temperatu...

Page 21: ...de escarcha CONTROL DE LA VENTILACI N CON AIRE FRESCO El Fresh Air Vent Ventilaci n con aire fresco permite que el aparato de aire acondicionado haga circular el aire interior posici n OFF Apagada in...

Page 22: ...uidos ni coloque objetos pesados sobre el control remoto Aseg rese de que la se al del control remoto hasta el aparato de aire acondicionado est libre de obstrucciones REEMPLAZO DE LAS PILAS DEL CONTR...

Page 23: ...o de aire La habitaci n estaba demasiado caliente cuando comenz el proceso de enfriamiento Permita tiempo suficiente para que la unidad enfr e la habitaci n El selector de enfriamiento est fijado en L...

Page 24: ...bles normales Todos los repuestos bien nuevos o refabricados asumen como per odo de garant a s lo el periodo de tiempo restante por el cual el componente aplicable est expresamente garantizado en el p...

Reviews: