T-359
4–46
Table 4–9 DataCORDER Pre-trip Result Records
TEST #
TITLE
DATA
1-0
Heater On
Pass/Fail/Skip Result, Change in current for Phase A, B and C
1-1
Heater Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
2-0
Condenser Fan On
Pass/Fail/Skip Result, Water pressure switch (WPS) - Open/
Closed, Change in currents for Phase A, B and C
2-1
Condenser Fan Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-0
Low Speed Evaporator Fan On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
3-1
Low Speed Evaporator Fan Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-0
High Speed Evaporator Fan On
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
4-1
High Speed Evaporator Fan Off
Pass/Fail/Skip Result, Change in currents for Phase A, B and C
5-0
Supply/Return Probe Test
Pass/Fail/Skip Result, STS, RTS, SRS and RRS
5-1
Secondary Supply Probe (SRS) Test Pass/Fail/Skip
5-2
Secondary Return Probe (RRS) Test Pass/Fail/Skip
6-0
Discharge Thermistor Test
Pass/Fail/Skip
6-1
Suction Thermistor Test
Pass/Fail/Skip
6-2
Discharge Pressure Sensor Test
Pass/Fail/Skip
6-3
Suction Pressure Sensor Test
Pass/Fail/Skip
6-4
Compressor Current Draw Test
Pass/Fail/Skip
6-5
Compressor Leak Test
Pass/Fail/Skip
6-6
Economizer Valve Test
Pass/Fail/Skip
6-7
Digital Unloader Valve Test
Pass/Fail/Skip
7-0
High Pressure Switch Closed
Pass/Fail/Skip Result, AMBS, DPT or CPT (if equipped)
Input values that component opens
7-1
High Pressure Switch Open
Pass/Fail/Skip Result, STS, DPT or CPT (if equipped)
Input values that component closes
8-0
Perishable Mode Heat Test
Pass/Fail/Skip Result, STS, time it takes to heat to 16
C (60
F)
8-1
Perishable Mode Pulldown Test
Pass/Fail/Skip Result, STS,
time it takes to pull down to 0
C (32
F)
8-2
Perishable Mode Maintain Test
Pass/Fail/Skip Result, Averaged DataCORDER supply
temperature (SRS) over last recording interval.
9-0
Defrost Test
Pass/Fail/Skip Result, DTS reading at end of test, line voltage,
line frequency, time in defrost.
10-0
Frozen Mode Heat Test
Pass/Fail/Skip Result, STS, time unit is in heat.
10-1
Frozen Mode Pulldown Test
Pass/Fail/Skip Result, STS,
time to pull down unit to -17.8
C (0
F).
10-2
Frozen Mode Maintain Test
Pass/Fail/Skip Result, Averaged DataCORDER
return temperature (RRS) over last recording interval.
Summary of Contents for 69NT40-561-019
Page 2: ......
Page 4: ......
Page 74: ......
Page 127: ...8 3 T 359 Figure 8 2 SCHEMATIC DIAGRAM Evergreen Unit Configuration ...
Page 128: ...T 359 8 4 Figure 8 3 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 1 of 2 ...
Page 129: ...8 5 T 359 Figure 8 4 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 2 of 2 ...
Page 130: ......
Page 134: ......
Page 135: ......