![Carrier 69NT40-561-019 Operation And Service Manual Download Page 14](http://html1.mh-extra.com/html/carrier/69nt40-561-019/69nt40-561-019_operation-and-service-manual_2563845014.webp)
T-359
1–4
CAUTION
!
Allowing the scroll compressor to operate in reverse for more than two minutes will result in
internal compressor damage. Turn the start-stop switch OFF immediately.
CAUTION
!
To prevent trapping liquid refrigerant in the manifold gauge set be sure set is brought to suc-
tion pressure before disconnecting.
CAUTION
!
The scroll compressor achieves low suction pressure very quickly. Do not use the compressor
to evacuate the system below 0 psig. Never operate the compressor with the suction or dis-
charge service valves closed (frontseated). Internal damage will result from operating the com-
pressor in a deep vacuum.
CAUTION
!
Take necessary steps (place plywood over coil or use sling on motor) to prevent motor from
falling into condenser coil.
CAUTION
!
Do not remove wire harnesses from module unless you are grounded to the unit frame with a
static safe wrist strap.
CAUTION
!
Unplug all module connectors before per forming arc welding on any part of the container.
CAUTION
!
The unit must be OFF whenever a program ming card is inserted or removed from the control-
ler programming port.
CAUTION
!
Use care when cutting wire ties to avoid nicking or cutting wires.
CAUTION
!
Do not allow moisture to enter wire splice area as this may affect the sensor resistance.
Summary of Contents for 69NT40-561-019
Page 2: ......
Page 4: ......
Page 74: ......
Page 127: ...8 3 T 359 Figure 8 2 SCHEMATIC DIAGRAM Evergreen Unit Configuration ...
Page 128: ...T 359 8 4 Figure 8 3 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 1 of 2 ...
Page 129: ...8 5 T 359 Figure 8 4 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 2 of 2 ...
Page 130: ......
Page 134: ......
Page 135: ......