4–23
T-359
4.7.15
ISO Trip Header
DataLINE provides the user with an interface to view/ modify current settings of the ISO trip header through the
ISO Trip Header screen.
The ISO Trip Header screen is displayed when the user clicks on the “ISO Trip Header” button in the “Trip Func-
tions” Group Box on the System Tools screen.
F9 function - Provides the user with a shortcut for manually triggering the refresh operation. Before sending modi-
fied parameter values, the user must ensure that a successful connection is established with the controller.
If the connection is established with the DataCORDER, the current contents of the ISO Trip Header from the Data-
CORDER will be displayed in each field. If the connection is not established with the DataCORDER, all fields on
the screen will be displayed as “Xs”. If at any time during the display of the ISO Trip Header screen the connection
is not established or is lost, the user is alerted to the status of the connection.
After modifying the values and ensuring a successful connection has been made with the DataCORDER, click on
the “Send” button to send the modified parameter values.
The maximum allowed length of the ISO Trip Header is 128 characters. If the user tries to refresh the screen or
close the utility without sending the changes made on the screen to the DataCORDER, the user is alerted with a
message.
Table 4–4 Controller Configuration Variables
CONFIG #
TITLE
DEFAULT
OPTION
CnF02
Evaporator Fan Speed
dS (Dual)
SS (Single)
CnF03
Control Sensors
FOUr
duAL
CnF04
Dehumidification Mode
On
OFF
CnF08
Single Phase/3-Phase Evaporator Fan Motor
1Ph
3Ph
CnF09
Refrigerant Selection
r134a
r744
CnF11
Defrost “Off” Selection
noOFF
OFF
CnF15
Discharge Temperature Sensor
Out
In
CnF16
DataCORDER Present
On (Yes)
(Not Allowed)
CnF17
Discharge Pressure Sensor
Out (No)
In (Yes)
CnF18
Heater
Old (Low Watt)
nEW (High Watt)
CnF20
Suction Pressure Sensor
Out (No)
In (Yes)
CnF22
Economy Mode Option
OFF
Std, Full
CnF23
Defrost Interval Timer Save Option
noSAv
SAv
CnF24
Advanced Pre-trip Enhanced Test Series Option
Auto
Auto2, Auto 3
CnF25
Pre-trip Test Points/Results Recording Option
rSLtS
dAtA
CnF26
Heat Lockout Change Option
Set to -10C
Set to -5C
CnF27
Suction Temperature Display Option
Out
In
CnF28
Bulb Mode Option
NOr
bULb
CnF31
Probe Check Option
SPEC
Std
CnF32
Single Evaporator Fan Option
2EF0
(Not Allowed)
CnF33
Snap Freeze Option
OFF
SnAP
CnF34
Degree Celsius Lockout Option
bOth
F
CnF37
Electronic Temperature Recorder
rEtUR
SUPPL, bOth
CnF41
Lower DTT Setting
Out
In
CnF44
eAutoFresh Enabled
Out
LO, UP
Summary of Contents for 69NT40-561-019
Page 2: ......
Page 4: ......
Page 74: ......
Page 127: ...8 3 T 359 Figure 8 2 SCHEMATIC DIAGRAM Evergreen Unit Configuration ...
Page 128: ...T 359 8 4 Figure 8 3 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 1 of 2 ...
Page 129: ...8 5 T 359 Figure 8 4 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 2 of 2 ...
Page 130: ......
Page 134: ......
Page 135: ......