T-359
7–24
7. The display module will go blank briefly, then read “Pro donE” when the software loading has loaded. (If
a problem occurs while loading the software: the display will blink the message “Pro FAIL” or “bad 12V.”
Turn start-stop switch OFF and remove the card.)
8. Turn unit OFF, via start-stop switch (ST).
9. Remove the PCMCIA card from the programming/ software port and return the unit to normal operation
by placing the start-stop switch in the ON position.
10. Turn power on, and wait 15 seconds. The status LED will flash quickly, and there will be no display. The
controller is loading the new software into memory. This takes about 15 seconds.
When complete, the controller will reset and power up normally.
11. Wait for default display, setpoint on the left, and control temperature on the right.
12. Confirm software is correct using keypad code select 18 to view Cd18 XXXX.
13. Turn power off. Operational software is loaded.
b. Procedure for loading configuration software:
1. Turn unit OFF using start-stop switch (ST).
2. Insert software/programming PCMCIA card containing the following (example) files into the program-
ming/software port. (See
•
menuDDMM.ml3
, this file allows the user to select the file/program to upload into the controller.
•
cfYYMMDD.ml3
, multi-configuration file.
3. Turn unit ON using start-stop switch (ST).
4. Press the UP or DOWN arrow key until display reads Set UP.
5. Press the ENTER key on the keypad.
6. Press the UP or DOWN arrow key until display reads XXXX the message ruN COnFG. (If a defective
card is being used the display will blink the message “bAd CArd.” Turn start-stop switch OFF and
remove the card.)
7. Press the ENTER key on the keypad.
8. The display module will go blank briefly and then display “61001”, based on the operational software
installed.
9. Press the UP or DOWN ARROW key to scroll through the list to obtain the proper model dash number.
(If a defective card is being used, the display will blink the message “bAd CArd.” Turn start-stop switch
OFF and remove the card.)
10. Press the ENTER key on the keypad.
11. When the software loading has successfully completed, the display will show the message “EEPrM
donE.” (If a problem occurs while loading the soft ware, the display will blink the message “Pro FAIL” or
“bad 12V.” Turn start-stop switch OFF and remove the card.)
12. Turn unit OFF using start-stop switch (ST).
13. Remove the PCMCIA card from the programming/ software port and return the unit to normal operation
by placing the start-stop switch in the ON position.
14. Confirm correct model configuration using the key pad to choose code 20 (CD20). The model displayed
should match the unit serial number plate.
c. Procedure for setting the date and time:
1. Press the UP or DOWN arrow key until display reads Set TIM.
2. Press the ENTER key on the keypad.
Summary of Contents for 69NT40-561-019
Page 2: ......
Page 4: ......
Page 74: ......
Page 127: ...8 3 T 359 Figure 8 2 SCHEMATIC DIAGRAM Evergreen Unit Configuration ...
Page 128: ...T 359 8 4 Figure 8 3 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 1 of 2 ...
Page 129: ...8 5 T 359 Figure 8 4 UNIT WIRING DIAGRAM Evergreen Unit Configuration Sheet 2 of 2 ...
Page 130: ......
Page 134: ......
Page 135: ......