background image

EN

ES

FR

IT

DE

PT

5

How to remove the drain cap

Clip the drain cap by 
needle-nose pliers and 
pull out.

How to fi x the drain cap

1) Insert hexagon 
 

wrench (4 mm) 

 

in a center head.

4 mm

2)  Firmly insert the drain cap.

Firmly insert the drain hose and drain cap; otherwise, water 
may leak.

In case of right or left piping

•  After scribing slits of the front
  panel with a knife or a making-off 

pin, cut them with a pair of 

  nippers or an equivalent tool. 

In case of bottom right or bottom left 
piping

•  After scribing slits of the front 
  panel with a knife or a 
  making-off pin, cut them with 
  a pair of nippers or an equivalent tool. 

Left-hand connection with piping

•  Bend the connecting pipe so that it is laid within 43 mm above 

the wall surface. If the connecting pipe is laid exceeding 43 
mm above the wall surface, the indoor unit may unstably be 
set on the wall.

 

When bending the connecting pipe, make sure to use a spring 
bender so as not to crush the pipe.

Bend the connecting pipe within a radius of 30 mm.

To connect the pipe after installation of the unit (fi gure)

80

270 mm

230 mm 

m

m

3

4

NOTE

If the pipe is bent incorrectly, the indoor unit may unstably be 
set on the wall.
After passing the connecting pipe through the pipe hole, con-
nect the connecting pipes to the auxiliary pipes and wrap the 
facing tape around them.

•  Bind the auxiliary pipes (two) and connecting cable with 

facing tape tightly. In case of leftward piping and rear-
leftward piping, bind the auxiliary pipes (two) only with 
facing tape.

Indoor unit

Connecting cable

Auxiliary pipes

Installation plate

•  Carefully arrange pipes so that any pipe does not stick 

out of the rear plate of the indoor unit.

•  Carefully connect the auxiliary pipes and connecting 

pipes to one another and cut off the insulating tape 
wound on the connecting pipe to avoid double-taping at 
the joint; moreover, seal the joint with the vinyl tape, etc.

•  Since dewing results in a machine trouble, make sure to 

insulate both connecting pipes. (Use polyethylene foam 
as insulating material.)

• When bending a pipe, carefully do it, not to crush it. 

Indoor Unit Fixing

1.  Pass the pipe through the hole in the wall and hook the 

indoor unit on the installation plate at the upper hook.

2.  Swing the indoor unit to right and left to confi rm that it is 

fi rmly hooked up on the installation plate.

3.  While pressing the indoor unit onto the wall, hook it at the 

lower part on the installation plate. Pull the indoor unit 
toward you to confi rm that it is fi rmly hooked up on the 
installation plate.

• For detaching the indoor unit 

from the installation plate, pull 
the indoor unit toward you while 
pushing its bottom up at the 
specifi ed parts.

Drainage

1.  Run the drain hose sloped downwards.

2.  Put water in the drain pan and make sure that the water is 

drained out of doors.

NOTE

•  The hole should be made at a slight downward slant on the 

outdoor side.

CAUTION

CAUTION

No gap

Do not apply lubricating oil
(refrigerant machine oil) when
inserting the drain cap. Application
causes deterioration and drain
leakage of the plug.

Insert a hexagon
wrench (4 mm).

Slit

Slit

Liquid side

Gas side

(To the forefront of fl are)

Outward form of indoor unit

R 30 mm (Use polisin (polyethylene)
core or the like for bending pipe.)

Use the handle of screwdriver, etc.

1

2

1

Hook here.

Installation plate

Hook

Press

(unhook)

Push

Push

Do not rise the
drain hose.

Do not form the
drain hose into
a wavy shape.

Do not put the
drain hose end
in the drainage ditch.

Do not put the
drain hose end
into water.

50 mm
or more

1110251169-EN.indd 5

1110251169-EN.indd   5

3/21/08 4:30:06 PM

3/21/08   4:30:06 PM

Downloaded from AC-Manual.com Manuals

Summary of Contents for 38CSR010 Series

Page 1: ...QGRRU XQLW 65 6HULHV 65 6HULHV 2XWGRRU XQLW 65 6HULHV 65 6HULHV 63 7 7 3 167 7 21 0 18 1 6 6 0 8 6 1 21 6 7 1 9 b7 0 RYHU LQGG 0 Downloaded from AC Manual com Manuals...

Page 2: ...7 1 1 3 1 1 6 0 7 1 5 0 3 0 6 1 1 81 7 0 1 8 5 6XNX DGDQJ 3HPDVDQJDQ 3LOLKDQ 81 7 0 7HPSDW 3HPDVDQJDQ 0HPEXDW XEDQJ GDQ 0HPDVDQJ 3HODW 3HPDVDQJDQ HUMD LVWULN 6DPEXQJDQ DEHO 3HPDVDQJDQ 3LSD GDQ 3LSD 6D...

Page 3: ...ns CAUTION To disconnect the appliance from the main power supply DANGER WARNING For general public use Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheath...

Page 4: ...ulate the refrigerant pipes separately with insulation not together 2 3 8 4 Make sure to run the drain hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly...

Page 5: ...screwing it in the upper and lower parts to hook up the indoor unit 2 To mount the installation plate on a concrete wall with anchor bolts use the anchor bolt holes as illustrated in the below gure 3...

Page 6: ...d pull it toward you 2 Remove the terminal cover and cord clamp 3 Insert the connecting cable according to the local cords into the pipe hole on the wall 4 Take out the connecting cable through the ca...

Page 7: ...onnecting pipes to one another and cut off the insulating tape wound on the connecting pipe to avoid double taping at the joint moreover seal the joint with the vinyl tape etc Since dewing results in...

Page 8: ...n the nut with a spanner and torque wrench as shown in the gure Tightening connection Do not apply excess torque Otherwise the nut may crack depending on the conditions Unit N m Outer dia of copper pi...

Page 9: ...Wiring Connection 1 Remove the valve cover from the outdoor unit 2 Connect the connecting cable to the terminals as identi ed with their respective matched numbers on the terminal block of indoor and...

Page 10: ...g a unit two units may receive the remote control signal simultaneously and operate In this case the operation can be preserved by setting either one indoor unit or remote control to B setting Both ar...

Reviews: