background image

EN

ES

FR

IT

DE

PT

3

INDOOR UNIT

INDOOR UNIT

Installation Place

•  A place which provides the spaces around the indoor unit as 

shown in the diagram

•  A place where there are no obstacles near the air inlet and 

outlet

•  A place which allows easy installation of the piping to the 

outdoor unit

•  A place which allows the front panel to be opened
•  The indoor unit shall be installed as top of the indoor unit 

comes to at least 2 m height. Also, it must be avoided to put 
anything on the top of the indoor unit.

•  Direct sunlight to the indoor unit’s wireless receiver should 

be avoided.

• The microprocessor in the indoor unit should not be too 

close to RF noise sources.

  (For details, see the owner’s manual.)  

     Remote control

•  A place where there are no obstacles such as a curtain that 

may block the signal from the indoor unit

•  Do not install the remote control in a place exposed to direct 

sunlight or close to a heating source such as a stove.

•  Keep the remote control at least 1 m apart from the nearest 

TV set or stereo equipment. (This is necessary to prevent 
image disturbances or noise interference.)

•  The location of the remote control should be determined as 

shown below.

65 mm

100 mm

80

100

180

Cutting a Hole and Mounting

Installation Plate

NOTE

•  When drilling a wall that contains a metal lath, wire lath or 

metal plate, be sure to use a pipe hole brim ring sold sepa-
rately.

     Cutting a hole

When installing the refrigerant pipes from the rear

     Mounting the installation plate

When the installation plate is directly
mounted on the wall

1. Securely fi t the installation plate onto the wall by screwing it 

in the upper and lower parts to hook up the indoor unit.

2.  To mount the installation plate on a concrete wall with anchor 

bolts, use the anchor bolt holes as illustrated in the below 
fi gure.

3.  Install the installation plate horizontally in the wall.

When installing the installation plate with a mounting screw, 
do not use the anchor bolt holes. Otherwise, the unit may fall 
down and result in personal injury and property damage.  

Failure to fi rmly install the unit may result in personal injury 
and property damage if the unit falls.

•  In case of block, brick, concrete or similar type walls, make 

5 mm dia. holes in the wall.

•  Insert clip anchors for appropriate mounting screws 

7

.

NOTE

•  Secure four corners and lower parts of the installation plate 

with 4 to 6 mounting screws to install it.

Electrical Work

1.  The supply voltage must be the same as the rated voltage 

of the air conditioner.

2.  Prepare the power source for exclusive use with the air 

conditioner.

NOTE

•  Wire type : More than H07RN-F or 245 IEC66

1.  After determining the pipe hole position on the mounting 

plate (

¨

), drill the pipe hole (Ø65 mm) at a slight downward 

slant to the outdoor side.

CAUTION

CAUTION

CAUTION

5

4

°

45

°

5

7

°

(Side view)

(Top view)

Indoor unit

Reception range

Remote
control

Remote
control

Reception
range

Indoor unit

The center of the pipe 
hole is above the arrow.

Pipe hole

Installation plate
(Keep horizontal direction.)

5 mm dia. hole

Clip anchor
(local parts)

7

Mounting screw
Ø4 x 25

R

Anchor bolt

Projection
15 mm or less

62

85

82.5

170

7

1

Anchor bolt holes

Hook

Hook

Hook

Pipe hole

Pipe hole

Installation
plate

 Mounting screw

Weight

Indoor unit

Thread

2 m or more from fl

 oor

1110251169-EN.indd 3

1110251169-EN.indd   3

3/21/08 4:30:03 PM

3/21/08   4:30:03 PM

Downloaded from AC-Manual.com Manuals

Summary of Contents for 38CSR010 Series

Page 1: ...QGRRU XQLW 65 6HULHV 65 6HULHV 2XWGRRU XQLW 65 6HULHV 65 6HULHV 63 7 7 3 167 7 21 0 18 1 6 6 0 8 6 1 21 6 7 1 9 b7 0 RYHU LQGG 0 Downloaded from AC Manual com Manuals...

Page 2: ...7 1 1 3 1 1 6 0 7 1 5 0 3 0 6 1 1 81 7 0 1 8 5 6XNX DGDQJ 3HPDVDQJDQ 3LOLKDQ 81 7 0 7HPSDW 3HPDVDQJDQ 0HPEXDW XEDQJ GDQ 0HPDVDQJ 3HODW 3HPDVDQJDQ HUMD LVWULN 6DPEXQJDQ DEHO 3HPDVDQJDQ 3LSD GDQ 3LSD 6D...

Page 3: ...ns CAUTION To disconnect the appliance from the main power supply DANGER WARNING For general public use Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheath...

Page 4: ...ulate the refrigerant pipes separately with insulation not together 2 3 8 4 Make sure to run the drain hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly...

Page 5: ...screwing it in the upper and lower parts to hook up the indoor unit 2 To mount the installation plate on a concrete wall with anchor bolts use the anchor bolt holes as illustrated in the below gure 3...

Page 6: ...d pull it toward you 2 Remove the terminal cover and cord clamp 3 Insert the connecting cable according to the local cords into the pipe hole on the wall 4 Take out the connecting cable through the ca...

Page 7: ...onnecting pipes to one another and cut off the insulating tape wound on the connecting pipe to avoid double taping at the joint moreover seal the joint with the vinyl tape etc Since dewing results in...

Page 8: ...n the nut with a spanner and torque wrench as shown in the gure Tightening connection Do not apply excess torque Otherwise the nut may crack depending on the conditions Unit N m Outer dia of copper pi...

Page 9: ...Wiring Connection 1 Remove the valve cover from the outdoor unit 2 Connect the connecting cable to the terminals as identi ed with their respective matched numbers on the terminal block of indoor and...

Page 10: ...g a unit two units may receive the remote control signal simultaneously and operate In this case the operation can be preserved by setting either one indoor unit or remote control to B setting Both ar...