PRECAUTIONS FOR SAFETY

PRECAUTIONS FOR SAFETY

•  FOR USE BY QUALIFIED PERSONS ONLY.
•   TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES 

ARE OFF.

  FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK.
•  CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC 

PARTS MAY BE DAMAGED.

•  CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION.
•  DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS.
  FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION.
•  TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE 

THAN 2 M) FROM HEAT SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC.

•  WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO 

GET THE SPECIFIED REFRIGERANT (R22) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR 
OR ANY OTHER GAS IS MIXED IN THE REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES 
ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF THE PIPE AND INJURIES ON PERSONS.

•  IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY 

LET FRESH AIR INTO THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES 
GENERATION OF POISONOUS GAS.

This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at 
least 3 mm in all poles. If this is not possible, a power supply plug with earth must be used. This plug must be easily accessible after 
installation. The plug must be disconnected from the power supply socket in order to disconnect the appliance completely from the
mains.

CAUTION

To disconnect the appliance from the main power supply

DANGER

WARNING

For general public use

Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheathed fl exible cord (design H07RN-F) or 
cord designation 245 IEC66 (1.5 mm

2

 or more). (Shall be installed in accordance with national wiring regulations.)

•  Never modify this unit by removing any of the safety guards or bypassing any of the safety interlock switches.
•  Do not install in a place which cannot bear the weight of the unit.
  Personal injury and property damage can result if the unit falls.
•  Before doing the electrical work, attach an approved plug to the power supply cord.
  Also, make sure the equipment is properly earthed.
•  Appliance shall be installed in accordance with national wiring regulations.
  If you detect any damage, do not install the unit. Contact your Carrier dealer immediately.

•  Exposure of unit to water or other moisture before installation could result in electric shock.
  Do not store it in a wet basement or expose to rain or water.
•  After unpacking the unit, examine it carefully for possible damage.
•  Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the 

unit or where noise and discharged air might disturb neighbors.

•  To avoid personal injury, be careful when handling parts with sharp edges.
•  Please read this installation manual carefully before installing the unit. It contains further important instructions for proper

installation.

CAUTION

REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER

Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience 
any problems or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures.

1110251169-EN.indd 1

1110251169-EN.indd   1

3/21/08 4:30:01 PM

3/21/08   4:30:01 PM

Downloaded from AC-Manual.com Manuals

Summary of Contents for 38CSR010 Series

Page 1: ...QGRRU XQLW 65 6HULHV 65 6HULHV 2XWGRRU XQLW 65 6HULHV 65 6HULHV 63 7 7 3 167 7 21 0 18 1 6 6 0 8 6 1 21 6 7 1 9 b7 0 RYHU LQGG 0 Downloaded from AC Manual com Manuals...

Page 2: ...7 1 1 3 1 1 6 0 7 1 5 0 3 0 6 1 1 81 7 0 1 8 5 6XNX DGDQJ 3HPDVDQJDQ 3LOLKDQ 81 7 0 7HPSDW 3HPDVDQJDQ 0HPEXDW XEDQJ GDQ 0HPDVDQJ 3HODW 3HPDVDQJDQ HUMD LVWULN 6DPEXQJDQ DEHO 3HPDVDQJDQ 3LSD GDQ 3LSD 6D...

Page 3: ...ns CAUTION To disconnect the appliance from the main power supply DANGER WARNING For general public use Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheath...

Page 4: ...ulate the refrigerant pipes separately with insulation not together 2 3 8 4 Make sure to run the drain hose sloped downward Do not allow the drain hose to get slack Cut the piping hole sloped slightly...

Page 5: ...screwing it in the upper and lower parts to hook up the indoor unit 2 To mount the installation plate on a concrete wall with anchor bolts use the anchor bolt holes as illustrated in the below gure 3...

Page 6: ...d pull it toward you 2 Remove the terminal cover and cord clamp 3 Insert the connecting cable according to the local cords into the pipe hole on the wall 4 Take out the connecting cable through the ca...

Page 7: ...onnecting pipes to one another and cut off the insulating tape wound on the connecting pipe to avoid double taping at the joint moreover seal the joint with the vinyl tape etc Since dewing results in...

Page 8: ...n the nut with a spanner and torque wrench as shown in the gure Tightening connection Do not apply excess torque Otherwise the nut may crack depending on the conditions Unit N m Outer dia of copper pi...

Page 9: ...Wiring Connection 1 Remove the valve cover from the outdoor unit 2 Connect the connecting cable to the terminals as identi ed with their respective matched numbers on the terminal block of indoor and...

Page 10: ...g a unit two units may receive the remote control signal simultaneously and operate In this case the operation can be preserved by setting either one indoor unit or remote control to B setting Both ar...