Broadmore 1750 - Release 4.6
Glossary-7
Glossary
Constant Bit Rate
An ATM service category that supports a constant or guaranteed rate to transport services such
as video or voice as well as circuit emulation requiring rigorous timing control and performance
parameters.
Circuit Emulation Service (CES)
The ATM Forum circuit emulation service interoperability specification provides
interoperability agreements for supporting constant bit rate (CBR) traffic over ATM networks
that comply with the other ATM Forum interoperability agreements. Specifically, this
specification supports emulation of existing TDM circuits over ATM networks.
End-to-End Timing Requirements
Timing requirements that address the restrictions on the amount of time a cell can take in getting
from source to destination.
Point-to-Point Connection
A connection with two endpoints (default in CES-CBR configuration).
Point-to-Multipoint Connection
A collection of associated ATM VC or VP links, with associated endpoint nodes, with the
following properties:
1.
One ATM link, called the Root Link, serves as the root in a simple tree
topology. When the Root Node sends information, all the remaining
nodes on the connection, called the Leaf Nodes, receive copies of the
information.
2.
Each of the Leaf Nodes on the connection can send information directly
to the Root Node. The Root Node cannot distinguish which Leaf is
sending information without additional (higher layer) information.
3.
The Leaf Nodes cannot communicate directly to each other with this
connection type.
Summary of Contents for Broadmore 1750
Page 1: ...Broadmore TM 1750 USER MANUAL Part Number 770 0020 DC Product Release 4 6 January 2008 ...
Page 24: ...xii Broadmore 1750 Release 4 6 Table of Contents ...
Page 50: ...1 26 Broadmore 1750 Release 4 6 Product Description Alarm Power Module IOM ...
Page 69: ...CHAPTER 3 Receipt of Product In this Chapter Receipt 3 2 Unpacking 3 2 Inspection 3 3 ...
Page 72: ...3 4 Broadmore 1750 Release 4 6 Receipt of Product Damage Reporting ...
Page 82: ...4 10 Broadmore 1750 Release 4 6 Chassis Installation and Grounding AC Power Supply Tray ...
Page 114: ...6 16 Broadmore 1750 Release 4 6 Electrical Installation Software ...
Page 188: ...7 74 Broadmore 1750 Release 4 6 Configuration Help ...
Page 234: ...8 46 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Summary of Front Panel LEDs ...
Page 244: ...9 10 Broadmore 1750 Release 4 6 Command Line Interface About Command ...
Page 266: ...10 22 Broadmore 1750 Release 4 6 Security Management FTP Login ...
Page 302: ...11 36 Broadmore 1750 Release 4 6 Security Management FIPS Mode sshdShow ...
Page 318: ...11 52 Broadmore 1750 Release 4 6 Security Management FIPS Mode Sanitation Procedures ...
Page 362: ...12 44 Broadmore 1750 Release 4 6 SNMP Configuration Notify Profiles ...
Page 370: ...A 8 Broadmore 1750 Release 4 6 Technical Specifications E3 Unstructured Circuit Emulation SAM ...
Page 373: ...APPENDIX C Software Error Messages In this Appendix Overview System Errors Setup Errors ...
Page 383: ...APPENDIX E Chassis Differences ...
Page 386: ...E 4 Broadmore 1750 Release 4 6 Chassis Differences Software Differences ...
Page 394: ...F 8 Broadmore 1750 Release 4 6 IPv6 Support Deleting a Network Route ...
Page 398: ...G 4 Broadmore 1750 Release 4 6 Broadmore Command List Commands Available at the CLI Prompt ...
Page 408: ...Glossary 10 Broadmore 1750 Release 4 6 Glossary ...