7-58
Broadmore 1750 - Release 4.6
Configuration
Unstructured E3-3 SAM
Table 7-13: Unstructured E3-3 SAM Operational Configuration
Item
Options
Comments
Port Name
A descriptive field to identify the port
Port Mode
On-line
Off-line
This is a status field that can be toggled to
off-line,
in which case the port will
not be available to make calls and passive SVCs are refused.
Framing
G.751
G.832
Unframed
G.751
is a European framing standard used for PDH applications.
G.832
is a European framing standard set by the ITU for transporting SDH
elements on PDH network.
Unframed
requires a 44.736 Mbps input.
Clock Mode
SRTS
Adaptive
Network
BITS Clock
Loop
NOTE: SRTS is a proprietary timing algorithm and may ONLY
be used with specific written prior permission from Carrier Access
Corporation. Additional license fees may apply.
SRTS
measures the Service Clock input frequency against a network-wide
ATM synchronization clock and sends the difference signals in the AAL1
header to the destination Broadmore 1750 circuit emulation interface. The
different signals are then combined with the network-wide ATM
synchronization clock to re-create the input service clock. If more than one
ATM clock synchronization is present in the network, an alternate timing
recovery method must be selected. For this method to work, the ATM network
must be synchronized to a single network-wide clock source. User equipment
should be configured to internal clock.
Adaptive
Timing
maintains a pre-defined fill level in the Circuit Emulation
Re-assembly buffer to control the timing output to user equipment. This
method of timing recovery does not require a Synchronous ATM network and
is used in applications where network wide synchronization is not available.
(Synchronous) Network
method of clock recovery derives timing from the
ATM Network and propagates it to the CE Service Interface. The ATM
network must be synchronized to a single source clock. User equipment should
be configured to recover timing from the Broadmore 1750 CE service
interface.
(Synchronous) Loop
CE interface will derive clock from the attached E3 user
equipment and transmit from the CE interface at that rate. The user equipment
should be configured for Internal timing if the Broadmore 1750 CE service
interface is configured for Synchronous loop.
BITS-
(Building Integrated Timing Supply) distributes standard timing to
equipment within the central office. The Broadmore 1750 accepts BITS via
either NIM IOM. The fallback for the primary BITS clock is the other BITS
clock. The fallback for no BITS is the internal clock of the NIM.
Summary of Contents for Broadmore 1750
Page 1: ...Broadmore TM 1750 USER MANUAL Part Number 770 0020 DC Product Release 4 6 January 2008 ...
Page 24: ...xii Broadmore 1750 Release 4 6 Table of Contents ...
Page 50: ...1 26 Broadmore 1750 Release 4 6 Product Description Alarm Power Module IOM ...
Page 69: ...CHAPTER 3 Receipt of Product In this Chapter Receipt 3 2 Unpacking 3 2 Inspection 3 3 ...
Page 72: ...3 4 Broadmore 1750 Release 4 6 Receipt of Product Damage Reporting ...
Page 82: ...4 10 Broadmore 1750 Release 4 6 Chassis Installation and Grounding AC Power Supply Tray ...
Page 114: ...6 16 Broadmore 1750 Release 4 6 Electrical Installation Software ...
Page 188: ...7 74 Broadmore 1750 Release 4 6 Configuration Help ...
Page 234: ...8 46 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Summary of Front Panel LEDs ...
Page 244: ...9 10 Broadmore 1750 Release 4 6 Command Line Interface About Command ...
Page 266: ...10 22 Broadmore 1750 Release 4 6 Security Management FTP Login ...
Page 302: ...11 36 Broadmore 1750 Release 4 6 Security Management FIPS Mode sshdShow ...
Page 318: ...11 52 Broadmore 1750 Release 4 6 Security Management FIPS Mode Sanitation Procedures ...
Page 362: ...12 44 Broadmore 1750 Release 4 6 SNMP Configuration Notify Profiles ...
Page 370: ...A 8 Broadmore 1750 Release 4 6 Technical Specifications E3 Unstructured Circuit Emulation SAM ...
Page 373: ...APPENDIX C Software Error Messages In this Appendix Overview System Errors Setup Errors ...
Page 383: ...APPENDIX E Chassis Differences ...
Page 386: ...E 4 Broadmore 1750 Release 4 6 Chassis Differences Software Differences ...
Page 394: ...F 8 Broadmore 1750 Release 4 6 IPv6 Support Deleting a Network Route ...
Page 398: ...G 4 Broadmore 1750 Release 4 6 Broadmore Command List Commands Available at the CLI Prompt ...
Page 408: ...Glossary 10 Broadmore 1750 Release 4 6 Glossary ...