Technical Specifications
Testing & Diagnostics
Testing & Diagnostics
Network loop-backs (structured DS3: DS3 port; unstructured DS3, E3 port)
Service loop-backs (structured DS3: DS3 port, tributary and DS0; unstructured
DS3, E3)
Internal BERT generation and monitoring (structured DS3, unstructured DS3,
E3)
FEAC loop-back generation and detection
Power
–48 VDC dual inputs, labeled A and B
240 W maximum for fully populated system
10 watts per NIM
8 watts per SAM
20 watts per CPU
Fused at 7.5 A, each input
Alarm power module, 1 slot
Over-voltage threshold: 58 ± 1.5 VDC
Under-voltage threshold: 38 ± 0.72 VDC
Optional Dual Redundant AC Power Supply, external
Regulatory Approvals
FCC Part 15, Class A radiated emissions
ANSI/UL 60950, CSA-C22.2 NO. 60950-00
FIPS-140-2 Validated
Joint Interoperability Test Command (JITC) Certified
DISA Information Assurance (IA) Tested
Network Equipment Building Standard (NEBS) Validated, Level 3
Summary of Contents for Broadmore 1750
Page 1: ...Broadmore TM 1750 USER MANUAL Part Number 770 0020 DC Product Release 4 6 January 2008 ...
Page 24: ...xii Broadmore 1750 Release 4 6 Table of Contents ...
Page 50: ...1 26 Broadmore 1750 Release 4 6 Product Description Alarm Power Module IOM ...
Page 69: ...CHAPTER 3 Receipt of Product In this Chapter Receipt 3 2 Unpacking 3 2 Inspection 3 3 ...
Page 72: ...3 4 Broadmore 1750 Release 4 6 Receipt of Product Damage Reporting ...
Page 82: ...4 10 Broadmore 1750 Release 4 6 Chassis Installation and Grounding AC Power Supply Tray ...
Page 114: ...6 16 Broadmore 1750 Release 4 6 Electrical Installation Software ...
Page 188: ...7 74 Broadmore 1750 Release 4 6 Configuration Help ...
Page 234: ...8 46 Broadmore 1750 Release 4 6 Maintenance and Troubleshooting Summary of Front Panel LEDs ...
Page 244: ...9 10 Broadmore 1750 Release 4 6 Command Line Interface About Command ...
Page 266: ...10 22 Broadmore 1750 Release 4 6 Security Management FTP Login ...
Page 302: ...11 36 Broadmore 1750 Release 4 6 Security Management FIPS Mode sshdShow ...
Page 318: ...11 52 Broadmore 1750 Release 4 6 Security Management FIPS Mode Sanitation Procedures ...
Page 362: ...12 44 Broadmore 1750 Release 4 6 SNMP Configuration Notify Profiles ...
Page 370: ...A 8 Broadmore 1750 Release 4 6 Technical Specifications E3 Unstructured Circuit Emulation SAM ...
Page 373: ...APPENDIX C Software Error Messages In this Appendix Overview System Errors Setup Errors ...
Page 383: ...APPENDIX E Chassis Differences ...
Page 386: ...E 4 Broadmore 1750 Release 4 6 Chassis Differences Software Differences ...
Page 394: ...F 8 Broadmore 1750 Release 4 6 IPv6 Support Deleting a Network Route ...
Page 398: ...G 4 Broadmore 1750 Release 4 6 Broadmore Command List Commands Available at the CLI Prompt ...
Page 408: ...Glossary 10 Broadmore 1750 Release 4 6 Glossary ...