42
WM5-96 Instruction Manual
Wiring diagrams
L
N
-
+
F
A1
A2
S
E
R
IA
L
C
O
N
V
E
R
T
E
R
Power supply, analogue and digital output modules
Digital inputs
RS485 serial port (AR1034 9600bps, AR2040 115200bps)
AO1037.
4 open collector outputs. This wiring
diagram is also valid for the open collector mod-
ules with 1 or 2 outputs. The load resistances
(Rc) must be designed so that the close contact
current is lower than 100mA; the VDC voltage
must be lower than or equal to 30VDC.
2-wire connection.
Other WM5-96
(a)
provided with RS485 are con-
nected in parallel
(b)
. Serial RS485-RS232 converter.
Termination of the serial port
(T)
:
it’s carried out only on the last
instrument of the network, by means of a jumper between (Rx+) and
(T).
4-wire connection.
Other WM5-96
(a)
provided with RS485 are col-
lected in parallel
(b).
Serial RS485-RS232 converter.
Terminatio of the serial port
(T)
:
it is carried out only on the last
instrument of the network, by means of a jumper between (Rx+) and
(T).
S
E
R
IA
L
C
O
N
V
E
R
T
E
R
T
T
a
a
b
b
AQ1042.
Connection by means of
NPN transistors.
AQ1042.
Connection by means of
PNP transistors.
AQ1042.
Connection by means of
contacts.
AQ1038.
Connection by
means of contacts.
AO1058.
1 relay output
AO1035.
2 relay outputs
AP1020.
AP1021.
Power supply.
F= 1.25 A T
AO2050.
2 analogue outputs
0-20mA DC.
AO2052.
2 analogue outputs
-5/+5mA DC.
AO2051.
2 analogue outputs
10V DC.
Summary of Contents for WM5-96 - PROGRAMMING
Page 1: ...WM5 96 Smart Power Quality Analyzer Instruction manual...
Page 2: ......
Page 12: ......