14
Programming WM5 96
This function allows the user to select the calculation method of the
DMD/AVG value of the selected variable. To access these functions
select DMD/AVG CALCUL. from the main menu by means of the “
” keys and confirm the selection with “S”
(1)
.
TYPE
(2)
: select the type of calculation mode to be used for the
DMD/AVG calculation: FIXED or SLIDE
(3)
. Select the desired type
(3)
by means of the “
” keys and confirm with “S”.
TIME
(4)
: select the time interval for the DMD/AVG calculation (5, 10,
15, 20, 30, 60 minutes). Select the desired time
(5)
by means of the
“
” keys and confirm with “S”.
FIXED SELECTION:
if, for example, a time interval of 15 minutes has
been selected, the instrument will calculate the AVD/DMD value of the
measured variable and updates its value every 15 minutes.
SLIDING SELECTION:
if for example a time interval of 15 minutes has
been selected, the instrument calculates the AVG/DMD value and
updates its value at the beginning after the first 15 values and then
after every minute, thus generating a window whose width is of 15
minutes and that moves forward every minute.
SYNCHRONISM
(6)
: select the synchronization mode, that is the
method that controls the calculation method of the average/demand
according to the selected time. Select the type of desired synchronism
(7)
by means of the “
” keys and confirm with “S”.
OFF
(7)
: the synchronization calculation starts when you switch the
instrument on.
CLOCK
(7)
: the synchronization starts as soon as the first selected
integration time multiple expires. Example: by setting the integration
time at 10 minutes and the current time at 10:25, the synchronization
will start at 10:30.
CONTACT
(7)
: the synchronization starts at the status modification
(from ON to OFF or from OFF to ON) of one of the digital inputs pro-
grammed such as SYNCHRONIZATION or TARIFF (see “DIGITAL
INPUTS”). A consequent status change produces the reset and then
again the starting up of the synchronization.
DMD/AVG calculation
WM5-96 Instruction Manual
**********MMAAIINN MMEENNUU**********
RREEVV.. 11..44..22..66 ((AAVV55))
SYSTEM
CT RATIO
VT-PT RATIO
DMD/AVG. CALCUL.
******DDEEMMAANNDD//AAVVEERRAAGGEE******
TYPE
TIME
SYNC
1
2
3
> 2s
> 2s
Measure
> 2s
******DDEEMMAANNDD//AAVVEERRAAGGEE******
TIPO
TEMPO
SINCRONISM
FIXED
SLIDE
******DDEEMMAANNDD//AAVVEERRAAGGEE******
TYPE
TIME
SYNC
4
5
> 2s
> 2s
******DDEEMMAANNDD//AAVVEERRAAGGEE******
TIPO
TEMPO
SINCRONISMO
5 min
10 min
15 min
20 min
******DDEEMMAANNDD//AAVVEERRAAGGEE******
TYPE
TIME
SYNC
6
7
> 2s
> 2s
******DDEEMMAANNDD//AAVVEERRAAGGEE******
TIPO
TEMPO
SINCRONISMO
OFF
CLOCK
CONTACT
Where:
Pmax
is the maximum
power,
Pc
is the contractual
power,
t1
is the selected time
period for the calcula-
tion of the AVG/DMD
value.