MAINTENANCE
EN
AH-13-01-R8 (09/2022)
29 / 55
www.carlisleft.com
WARNING
!
8. Mount the applicator in a padded vise and turn the motor
on by turn the switch “ON”. Listen to the audible pitch of
the motor.
9. Alternately tighten (4) socket head screws until snug. If
motor shaft begins to slow (audible pitch changes), loosen
screws slightly to relieve binding. DO NOT over tighten
screws so that gasket is squeezed outward beyond the
outer dimension of the barrel.
MOTOR ASSEMBLY
REPLACEMENT
1. Follow instructions for removing the cable assembly and
motor assembly from the barrel (see “Cable Assembly
Replacement” in the “Maintenance” section).
2. Replace the motor as required.
3. Follow the assembly instructions for replacing the high
voltage cable (see “Cable Assembly Replacement” in
the “Maintenance” section).
HANDLE ASSEMBLY
1. Invert the applicator and remove the (4) socket head
cap screws and lock washers from the underside of the
handle assembly with a 9/64-inch hex key wrench. Refer
to Figure 18.
Figure 18: Handle Assembly Removal
Item #
Description
1
2
3
4
5
6
HANDLE ASSEMBLY REMOVAL
(Figure 18)
(2) Socket Head Screws
O-Ring
Bushing, Paint
(4) Lock Washers
(2) Socket Head Screws
Handle Assembly
Ensure the power is “OFF” to the 9060 power
supply prior to rotating the bell in step 8.
2. Remove the two bottom socket head screws from the
cable/motor assembly and remove the handle assembly
from the applicator assembly, taking care not to lose the
paint tube and o-ring.
3. Remove paint tube and o-ring from the barrel and clean
the exposed barrel surface and paint tube of any paint
residue. Refer to “Effects of Solvents” in the “Mainte-
nance” section.
4. Insert paint tube into the barrel opening until it bottoms.
5. Place a new o-ring over the exposed paint tube.
2
1
3
6
4
5
CAUTION
!
Over tightening of the (4) socket head screws can