OPERATION
EN
AH-13-01-R8 (09/2022)
23 / 55
www.carlisleft.com
WARNING
!
Figure 13: 9060 Micro Amp Meter
should indicate between 5 and 50 microamperes (.005 to .05
milliamperes). Readings outside the range may indicate a
possible paint resistance and/or target distance problem, or
component failure. See the “Troubleshooting Guide”, the
“Gun Output Test”, or the “Gun Short Circuit Current Test” in
the “Maintenance” section for troubleshooting procedures.
Gun Short Circuit Current (SCI) Test
1. Connect wire at contact brush to ground via microam-
pere meter.
All paints and solvents must be purged from
the applicator prior to performing these tests.
2. Activate the applicator by turning the switch to the “ON”
position to spin the electric motor and initiate high voltage.
3. Read SCI on remote microampere meter:
• SCI = 90 to 115 microamperes.
4. If SCI is low or high, see “Paint, High Voltage & SCI Test
Equipment” manual for SCI test procedure using test
probe TE-98-01 Part number 76652.
Figure 14: No. 2 Handgun Short Circuit Current Test Diagram
1
2
3
4
5
NO. 2 HANDGUN SHORT CIRCUIT CURRENT TEST DIAGRAM (Figure 14)
Item #
Description
9060 Digital µA Meter Readout
High Voltage Cable
19372 -XXX No. 2 Handgun
Earth Ground Connection to Brush
Microamp Meter or 76652 to Earth Ground
2
1
4
3
5
3
2
1
4