INSTALLATION
EN
AH-13-01-R8 (09/2022)
13 / 55
www.carlisleft.com
CAUTION
!
WA R N I N G
!
WA R N I N G
!
INSTALLATION
PRE-INSTALLATION
REQUIREMENTS
1. Provide approved electrical wiring to the power supply.
The 9060 power supply must be located a minimum of
6.1m (20’) outside of the hazardous spray area.
2. Make sure the operating location has adequate grounding
facilities, such as electrical conduit, steel building columns,
metal water pipes, or other earth grounded objects.
3. Furnish a paint pressure pot with air regulator (or other
accepted pressure system). The regulator MUST have
a reliable control, with a recommended gauge range of
0-2.1 bar (0-30 psig).
4. Provide proper ventilation. (See “Safety” section of
this manual.)
5. Ensure that the target object to be coated and all
surrounding objects are grounded to a known, earth
ground by a separate ground wire attachment.
SAFEGUARDS
When operating this equipment in the vicinity of
computers, word processors, and/or other electronic
equipment, special care MUST be taken to ensure
that damage does not occur from electrical energy
discharges. (See Ransburg “Safety Literature” for
further information regarding application.)
The following guidelines can be used:
• It is highly recommended, whenever possible, that ALL
electronic components or equipment be removed from
the spray area. This includes computer software such
as tapes, disks, diskettes, etc., located inside and/or
around the spray area.
EQUIPMENT INSTALLATION
Do not use the power supply ground wire to ground
target objects. The targets objects must have separate
true earth ground for best efficiency.
NEVER
wrap the applicator, associated valves and
tubing, and supporting hardware in plastic to keep it clean.
A surface charge may build up on the plastic surface and
discharge to the nearest grounded object. Efficiency of
the applicator will also be reduced and damage or failure
of the applicator’s components may occur.
WRAPPING THESE COMPONENTS IN PLASTIC
WILL VOID WARRANTY.
• If the static shielding of a unit is NOT KNOWN, all
electronic components (such as terminals, screens,
and cables) should be completely wrapped in
aluminum foil and grounded to a true earth ground.
• When painting electrical control panels or consoles,
wrap all push-buttons, switches, meters, or pilot lights
with aluminum foil and ground to the panel or other
earth ground.
Before attempting to install the equipment, ensure that
all the necessary components are available (see “Parts
Identification” section of this manual). In addition, read
all the technical and safety literature that is provided. If
the literature is not available, contact your local Ransburg
Distributor where the equipment was purchased.
The power source wiring and the power supply
connections to it
MUST
meet all local fire and electrical
code standards and comply with all appropriate local
and national health and safety codes.
All power supplies
MUST
be grounded to a known
true earth ground before any other connections are
made or functions performed.
DO NOT
use the power
supply ground wire to ground the target objects (use
LSME4000-00 clamp assembly)!