3. Operating Instructions
Temperature Controller Single or Double Ramp Operation (See Figure 1)
Single Ramp Operation: The temperature ramps in a predetermined amount of time from
ambient to a set point temperature and holds at that temperature for a required amount of
time.
Double Ramp Operation: The temperature ramps in a predetermined amount of time from
ambient to the first set point temperature and holds at that temperature for a required amount
of time, it then ramps in a predetermined amount of time to a second set point temperature and
holds at that temperature for a required amount of time.
Temperature Controller Displays
The upper display indicates the mode of the heating cycle and the process temperature. During
the Ramp mode the upper display will toggle between the process temperature and ramping.
Once the cure temperature (set point) has been reached the upper display will toggle between
the hold time remaining (in minutes) and the process temperature. When the hold time becomes
less than one minute the upper display will toggle between the hold time remaining (in seconds)
and the process temperature. The lower display indicates the cure temperature (set point).
Cycle Start Button
The product will heat to the set point temperature and remain there for the time selected. The
hold time will start when the temperature reaches 15°F before set point.
Heater Position
If the heater is too far from the product, the temperature will not be reached and the hold
timer will not be activated.
Summary of Contents for BGK AutoCure 6000-2216
Page 1: ...AutoCure 6000 2216 Overhead Heater Assembly and Operating Manual ...
Page 22: ......
Page 23: ......
Page 37: ......
Page 38: ......
Page 41: ...A DETAIL J SCALE0 40 1 REMOVET1 11SBOLTAFTERINSTAI I ATION ...
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ...AUTOCURE MODEL NUMBER AC6 2216 480 SP ...
Page 48: ......
Page 49: ......