6. Maintenance
The AutoCure™6000 will require some basic maintenance when used on a regular basis. Failure to
do so may degrade the performance of the unit.
Disconnect main power at the source before performing any maintenance procedures.
Actuator
1. Periodically check clevis ends for wear, cracks or distortion.
2. Periodically check the shoulder bolt/nut and 3/8” diameter rod for excessive wear.
3. Periodically apply a few drops of oil at these pivot points.
Pivot Points
1. Single head units have three (3) castle nut/spring combinations and two (2) shoulder bolts with
Nylock nuts. If pivot points become loose, heater positioning will not be maintained. Check
these points monthly.
2. Dual head units have seven (7) castle nut/spring combinations and two (2) shoulder bolts with
Nylock nuts. If pivot points become loose, heater positioning will not be maintained. Check
these points monthly.
3. To adjust spring tension; remove cotter pin, tighten castle nut (usually one or two notches) and
replace cotter pin through bolt.
Lamps, Reflectors and Heat Sensor (Pyrometer) Lens
1. Clean with soft cloth and alcohol monthly. Heat sensor accuracy is dependent on a clean lens.
Tension Spring/
Castle Nut
Nylock Nut
Tension Spring/
Castle Nut (4)
(under heater skin)
Tension Spring/
Castle Nut (2)
Tension Spring/
Castle Nut (2)
Single Head
Dual Head
Pyrometer
Summary of Contents for BGK AutoCure 6000-2216
Page 1: ...AutoCure 6000 2216 Overhead Heater Assembly and Operating Manual ...
Page 22: ......
Page 23: ......
Page 37: ......
Page 38: ......
Page 41: ...A DETAIL J SCALE0 40 1 REMOVET1 11SBOLTAFTERINSTAI I ATION ...
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ...AUTOCURE MODEL NUMBER AC6 2216 480 SP ...
Page 48: ......
Page 49: ......