Dynacode series
Ribbon save
10.15 Operating
manual 109
13.5 Standard ribbon save (intermittent mode)
Press key
to access the function menu.
Press key
as long as you arrive at the 'Ribbon save' menu.
Press key
to select the menu.
Press key
and to select the ribbon save mode 'Standard'.
Press key
to arrive ath the following menu item.
R-Correction
Please find the description of the function in chapter 13.2, page 102.
Press key
to arrive at the next menu item.
ExpertParameters:
This menu item is password protected. Enter password, press key
to confirm the input and the following parameters are indicated:
PhDownT = printhead down time in ms:
Is used from the ribbon save algorithm to calculate the start of the
printhead downwards movement.
PhUpT = printhead up time in ms:
Is used from the ribbon save algorithm to calculate if a field ribbon
save is possible or not.
Press key
to arrive at the next menu item.
PhVReactT = valve reaction time in ms:
The time is calculated when the printhead upwards movement is
started.
Press key
to arrive at the next menu item.
Tension / Ribbon Mode
Tension:
Indication of length that is transported forwards after
measuring the transfer ribbon.
Ribbon Mode:
0:
The transfer ribbon is retracted after each printout over the
complete print length, i.e. no ribbon save between the individual
layouts.
1:
The transfer ribbon is only retracted over the printed sector, i.e. the
gaps between the layouts were not optimised.
When changing the layouts, the transfer ribbon is positioned
automatically.