/2
Analogue probe measurement stability
4
1
15
-
M
NO
Digital inputs
DIA
Assign immediate external alarm digital input
0 = Function disabled
4 = digital input 4 (ID4)
1 = digital input 1 (ID1)
5 = digital input 5 (ID5)
2 = digital input 2 (ID2)
-1 = digital input seriale
3 = digital input 3 (ID3)
0
-1
5
-
S
NO
DIb
Assign delayed external alarm digital input - see DIA
0
-1
5
-
S
NO
DIc
Assign enable defrost digital input - see DIA
0
-1
5
-
S
NO
DId
Assign start defrost digital input - see DIA
0
-1
5
-
S
NO
DIE
Assign door switch with solenoid/comp. and evap. fans OFF digital input - see DIA
0
-1
5
-
S
NO
DIF
Assign remote ON/OFF digital input - see DIA
0
-1
5
-
S
NO
DIG
Assign curtain switch digital input - see DIA
0
-1
5
-
S
NO
DIH
Assign start/stop continuous cycle digital input - see DIA
0
-1
5
-
S
NO
DII
Assign input status monitoring digital input - see DIA
0
-1
5
-
S
NO
DIL
Assign timed digital input - see DIA
0
-1
5
-
S
NO
DIM
Assign Standby mode switch digital input - see DIA
0
-1
5
-
S
NO
DIn
Assign Clean mode switch digital input - see DIA
0
-1
5
-
S
NO
DIo
Assign working parameters set change digital input - see DIA
0
-1
5
-
S
NO
DIP
Assign door switch without control stop digital input - see DIA
0
-1
5
-
S
NO
DIr
Assign defrost according to DI status digital input - see DIA
0
-1
5
-
S
NO
rIA
Immediate external alarm digital input logic
0 = direct logic
1 = reverse logic
0
0
1
-
S
NO
rIb
Delayed external alarm digital input logic - see rIA
0
0
1
-
S
NO
rIc
Enable defrost digital input logic - see rIA
0
0
1
-
S
NO
rId
Start defrost digital input logic - see rIA
0
0
1
-
S
NO
rIE
Door switch with /solenoid comp. and fans OFF digital input logic - see rIA
0
0
1
-
S
NO
rIF
Remote ON/OFF digital input logic - see rIA
0
0
1
-
S
NO
rIG
Curtain switch digital input logic - see rIA
0
0
1
-
S
NO
RiH
Start/stop continuous cycle digital input logic - see rIA
0
0
1
-
S
NO
rII
Input status monitoring digital input logic - see rIA
0
0
1
-
S
NO
rIL
Timed digital input logic - see rIA
0
0
1
-
S
NO
rIM
Standby mode switch digital input logic - see rIA
0
0
1
-
S
NO
rIn
Clean mode switch digital input logic - see rIA
0
0
1
-
S
NO
rIo
Change working parameter configuration digital input logic - see rIA
0
0
1
-
S
NO
rIP
Door switch without control stop digital input - see rIA
0
0
1
-
S
NO
rIr
Defrost according to DI status digital input logic - see rIA
0
0
1
-
S
NO
A9
Select digital input broadcast from Master to Slaves (only on Master)
0 = from supervisor
3 = Digital input 3 (ID3)
1 = Digital input 1 (ID1)
4 = Digital input 4 (ID4)
2 = Digital input 2 (ID2)
5 = Digital input 5 (ID5)
0
0
5
-
S
NO
dIt
Timer duration (timed input)
0 = function disabled
0
0
999
min
S
NO
Digital outputs
DOA
Assign solenoid/comp. digital output
0 = not set
3 = digital output 3 (NO3)
1 = digital output 1 (NO1)
4 = digital output 4 (NO4)
2 = digital output 2 (NO2)
3
0
4
-
S
NO
DOb
Assign alarm digital output - see DOA
0
0
4
-
S
NO
DOc
Assign auxiliary digital output - see DOA
0
0
4
-
S
NO
DOd
Assign auxiliary serving the Master on the Slaves digital output - see DOA
0
0
4
-
S
NO
DOE
Assign light digital output - see DOA
4
0
4
-
S
NO
DOF
Assign light serving the Master on the Slaves digital output - see DOA
0
0
4
-
S
NO
86