“FLSTDMAHUE” +030220961 - rel. 1.1 - 28.08.2019
17
pCO
3
Large
AIR
INPUT
U1
DI5
U8
T
p
T
F1
AIR
OUTPUT
H%
U10
DO7
Y1, DI6
HUM
p
p
U4
T
DI3
U2
H%
U3
H%
U5
T
U9
T
DI7
p
F2
Y2
M
V1
P1
DO9
DO10
M
CO
2
U7
DO3,DO4,DO5
DI10
R
DO1, Y4
DI11
f1
f2
DO2, Y4
DI12
f1
f2
Y3
M
V2
P2
DO11 DO12
REC
M
DO6
p
DI17
Y5
Y6
U6
p
DI4
T1
H1
C1
C2
T2
T3
T4
H2
T5
H3
DI8
DI9
DI13
DI14
DI15
DI16
AL1
DI1
AL
DO8
On/Off
DI2
PR2
PR1
PR4
PR5
S1
S2
PR3
P2
P3
P4
DI10
Fig. 3.k
AI
Analogue inputs
AO
Analogue outputs
P1…4
Pumps
U1
Supply humidity
Y1
Humidifier
T
Temperature probe
U2
Outside humidity
Y2
Preheating valve
H
Humidity probe
U3
Return humidity
Y3
Cooling valve
C1
Preheating coil
U4
Supply temperature
Y4
Supply fan
C2
Cooling coil
U5
Return temperature
Y5
Outside/exhaust air damper
PR
Differential pressure switch/probe
U6
Differential pressure outlet air
Y6
Mixing damper
HUM
Humidifier
U7
CO2 probe
DI
Digital inputs
F1, F2
Filters
U8
Outside temperature
DI1
Generic alarm
AL
Generic alarm
U9
Frost protection temperature
DI2
Remote ON/OFF
AL1
Generic alarm
U10
Temperature downstream of coils
DI3
Supply air flow alarm
S1
Outside/exhaust damper
DO
Digital outputs
DI4
Return air flow alarm
S2
Mixing damper
DO1
Supply fan
DI5
Supply air filter alarm
R
Heater
DO2
Return fan
DI6
Humidifier alarm
DO3
Reheat heater 1
DI7
Return air filter alarm
DO4
Reheat heater 2
DI8
Supply fan thermal overload alarm
DO5
Reheat heater 3
DI9
Return fan thermal overload alarm
DO6
Bypass damper
DI10
Reheating heater thermal overload alarm
DO7
Humidifier
DI11
Supply fan inverter alarm
DO8
Generic alarm
DI12
Return fan inverter alarm
DO9
Preheating pump 1
DI13
Preheating pump 1 thermal overload alarm
DO10
Preheating pump 2
DI14
Preheating pump 2 thermal overload alarm
DO11
Cooling pump 1
DI15
Cooling pump 1 thermal overload alarm
DO12
Cooling pump 2
DI16
Cooling pump 2 thermal overload alarm
DI17
Dirty heat recovery unit alarm
Tab. 3.d
Fieldbus card
BMS card
!
J1
G
G0
J24
+Vterm
GND
+5Vref
J2
U1
GND
+VDC
U3
U2
J3
U4
GND
U5
GND
J4
VG
Y2
Y1
VG0
Y3
Y4
J5
ID1
ID4
ID3
ID2
ID5
IDC1
ID8
ID7
ID6
!
J12
C1
NO1
NO2
NO3
C1
J13
C4
NO4
NO5
NO6
C4
J14
C7
NO7
C7
NO8
C8
NC8
J15
J11
Rx-/Tx-
Rx+Tx+
GND
L
N
M
OUT
+V
analog output preheat valve (0 to 10 vdc)
analog output humidifier command (0 to 10 Vdc)
DO1
DO2
DO3
L
N
DO4
DO5
DO8
J6
U6
GND
U8
U7
J7
ID9
ID12
ID11
ID10
IDC9
C9
NO9
NO10
J16
NO11
C9
C12
NC12
J17
NO12
C13
NC13
NO13
J18
J8
ID13H
ID14
ID13
ID14H
IDC13
M
OUT
+V
M
OUT
+V
analog output supply air fan (0 to 10 vdc)
analog output cooling valve (0 to 10 vdc)
DO9
DO10
E+
GND
E-
J23
J22
C16
NO16
NO17
NO18
C16
J21
C14
NC14
NO15
C15
NC15
NO14
J19
ID15H
ID15
IDC15
ID16
ID16H
J20
Y5
GND
U9
Y6
U10
IDC17
ID18
ID17
GND
M
OUT
+V
M
OUT
+V
analog output external air damper (0 to 10 vdc)
analog output mixing air damper (0 to 10 vdc)
DO11
DO12
DO6
pCO5+ Large
Fig. 3.l