ir33+ VCC
+040000058 - rel. 1.2 - 15.02.2018
User
Par.
Description
Def.
Min
Max
UOM
Type Carel
SPV
ModBus® R/W
CnF
C
H0
Serial address
1
0
207
-
I
62
162
R/W
C
H1
"AUX1 output confi guration
0: normally energised alarm
1: normally de-energised alarm
2: Auxiliary
3: Light
4: Auxiliary evaporator defrost
5: Pump down valve
6: Condenser fan
7: Delayed compressor
8: Auxiliary with deactivation when OFF
9: Light with deactivation when OFF
10: No function
11: Reverse with neutral zone
12: Second compressor step
13: no function
14: drain heater"
10
0
14
-
I
63
163
R/W
C
H2
Disable keypad functions
1
0
6
-
I
64
164
R/W
C
H4
Buzzer: 0/1=enabled/disabled
0
0
1
-
D
56
56
R/W
C
H5
AUX2 output confi guration: see H1
10
0
13
-
I
66
166
R/W
C
H6
"Terminal keypad lock confi guration
0 = all buttons enabled"
0
0
255
-
I
67
167
R/W
C
H7
Keypad: 0 = standard; 1 = modifi ed
0
0
1
-
D
57
57
R/W
C
H8
Output switched with scheduler 0 = Light; 1= AUX
0
0
1
-
D
64
64
R/W
C
H9
Set point variation with scheduler 0/1 = no/yes
0
0
1
-
D
65
65
R/W
C
H10
AUX3 output confi guration - See H1
10
0
14
-
I
165
265
R/W
C
Hdn
Number of default parameter sets available
0
0
6
-
I
139
239
R
C
Hdh
"Anti-sweat heater off set
0 = anti-sweat heater function disabled (°C)
32 = anti-sweat heater function disabled (°F)"
0
-50
200
°C/°F
A
37
37
R/W
C
HrL
Remote light relay status on Master: 0 = disabled
0
0
1
-
D
66
66
R/W
C
HrA
Remote AUX relay status on Master: 0 = disabled
0
0
1
-
D
67
67
R/W
C
HSA
Remote controller alarms on Master: 0 = disabled
0
0
1
-
D
68
68
R/W
C
In
"Type of unit
0 = Normal - 1 = Master - 2…6 = Slave 1 to 5"
0
0
6
-
I
140
240
R/W
HcP
C
HAn
Number of HA alarms
0
0
0
-
I
69
169
R
C
HA…HA2
HA HACCP alarms activated (press Set)
-
-
-
-
-
-
-
-
C
HA_y__
Alarm 1 - Year
0
0
99
year
I
72
172
R
C
HA_M__
Alarm 1 - Month
0
1
12
month
I
73
173
R
C
HA_d__
Alarm 1 - Day of the month
0
1
7
day
I
74
174
R
C
HA_h__
Alarm 1 - Hour
0
0
23
hour
I
75
175
R
C
HA_m__
Alarm 1 - Minute
0
0
59
minute
I
73
173
R
C
HA_t__
Alarm 1 - Duration
0
0
99
hour
I
77
177
R
C
HA1_y__
Alarm 2 - Year
0
0
99
year
I
78
178
R
C
HA1_M__
Alarm 2 - Month
0
1
12
month
I
79
179
R
C
HA1_d__
Alarm 2 - Day of the month
0
1
7
day
I
80
180
R
C
HA1_h__
Alarm 2 - Hour
0
0
23
hour
I
81
181
R
C
HA1_m__
Alarm 2 - Minute
0
0
59
minute
I
79
179
R
C
HA1_t__
Alarm 2 - Duration
0
0
99
hour
I
83
183
R
C
HA2_y__
Alarm 3 - Year
0
0
99
year
I
84
184
R
C
HA2_M__
Alarm 3 - Month
0
1
12
month
I
85
185
R
C
HA2_d__
Alarm 3 - Day of the month
0
1
7
day
I
86
186
R
C
HA2_h__
Alarm 3 - Hour
0
0
23
hour
I
87
187
R
C
HA2_m__
Alarm 3 - Minute
0
0
59
minute
I
85
185
R
C
HA2_t__
Alarm 3 - Duration
0
0
99
hour
I
89
189
R
C
HFn
Number of HF alarms
0
0
0
-
I
70
170
R
C
HF…HF2
HF HACCP alarms activated (press Set)
-
-
-
-
-
-
-
-
C
HF_y__
Alarm 1 - Year
0
0
99
year
I
90
190
R
C
HF_M__
Alarm 1 - Month
0
1
12
month
I
91
191
R
C
HF_d__
Alarm 1 - Day of the month
0
1
7
day
I
92
192
R
C
HF_h__
Alarm 1 - Hour
0
0
23
hour
I
93
193
R