0330-0410-0M Rev D
•
Portable Digital Truck Scale
26
Refer to the Home run Connector Wiring Color Code Table below when
performing steps 4 through 7.
Homerun Connector Wiring Color Code Table
Connector
Signal
Homerun Cable
Wire Color
Wire Color if using a
Load Cell Cable
Pin Number Lever Color
1
BROWN
SHLD
GRAY
BROWN
2
WHITE
V+BUS
RED
WHITE
3
BLUE
V-BUS
BLACK
BLUE
4
BLACK
CAN H
WHITE
BLACK
5
GRAY
CAN L
BLUE or LIGHT BLUE
GRAY
4.
Looking at the end of the metal part of the connector where the wires are inserted, use your
fingernail and gently pull a wire clamp lever down away from the body of the connector.
5.
Insert the wire into the appropriate connector opening, and then close the wire clamp lever.
6.
Verify that the wire is being held securely in the connector by lightly pulling on the wire.
7.
Repeat steps 4 through 6 until all five wires of the homerun cable are installed in the metal
part of the connector.
Insert wire, then close
wire clamp lever to
secure wire in connector.
Gently pull
down to
open wire
clamp lever.