0330-0410-0M Rev D
•
Portable Digital Truck Scale
30
SCALE SETUP AND CONFIGURATION
Digital Scale Setup and Configuration
The SmartCell® digital load cells used in Cardinal Scale’s ARMOR® Portable Digital Truck
Scale are connected together using a daisy-chained CAN (Controller Area Network) cable. The
load cell connection loop can begin at any load cell on the scale, and may continue clockwise
or counter-clockwise if preferred.
For example, in the illustration below, the connection loop begins with load cell 4 and runs
clockwise ending with the end node terminator on load cell 6. Also note that there is not a
connection between load cell 4 and load cell 6.
IMPORTANT!
Be sure to insert the end node termination plug on the load cell at end
of the loop as shown in the example.
Example: Typical Truck Scale Configuration
NOTE:
If the loop were run in the other direction, the sequence would then be 6-8-7-5-3-1-2-4
with load cell 4 having the End Node Terminator installed on it.
Homerun Cable
7
1
2
3
6
5
8
End Node
Terminator
4
225D or 825D