background image

0330-0410-0M Rev D 

 Portable Digital Truck Scale 

24 

P1, CAN Connection to Scale (Homerun Cable) 

The P1 terminal block is used to connect the homerun cable between the 825D indicator and 

the first load cell in the loop (Start Node in the scale). Refer to the table below for terminal 

connections. 

 

825DLC Controller Card P1 Terminal Connections 

Board 

Label 

Homerun Cable 

Wire Color 

Wire Color if using a 

Load Cell Cable 

SHLD 

GRAY 

BROWN 

V+BUS 

RED 

WHITE 

V-BUS 

BLACK 

BLUE 

CAN H 

WHITE 

BLACK 

CAN L 

BLUE or LIGHT BLUE 

GRAY 

 

Micro USB 

This connector is used to perform firmware updates to the 825-DLC controller card. 

 

P6, Ethernet 

This connector is used to connect the 825D to your network to send information to iSite. 

 

P7, RS232 Serial Port 

The P7 pins are used to connect to Legacy iCAN, and for future connections. 

 

LED 1-4  

The LED’s are used for diagnostic purposes. For a complete explanation of their function, refer 

to the DIGITAL SCALE DIAGNOSTICS, Hardware Diagnostics section of this manual. 

 

 

Summary of Contents for ARMOR

Page 1: ...0330 0410 0M Rev D Portable Digital Truck Scale 1 Portable Digital Truck Scale Installation Manual...

Page 2: ...0330 0410 0M Rev D Portable Digital Truck Scale 2...

Page 3: ...FCC Compliance Statement This equipment generates uses can radiate radio frequency and if not installed and used in accordance with the instruction manual may cause interference to radio communicatio...

Page 4: ...0330 0410 0M Rev D Portable Digital Truck Scale II...

Page 5: ...7 Scale Section Installation 8 Optional Lifting Lugs 8 Load Cells and Load Cell Stands 9 Lower Frame Spacers Installation 12 Connect the Load Cell Cables 13 Install Homerun Cable 15 Maximum Homerun C...

Page 6: ...ard 1 38 DLC Card 1 Cell Assignment 39 Smart Calibration 43 Zero Calibration 52 Trim Cells 55 Span Adjust 61 Balancing Weighbridge Dead Load 64 DIAGNOSTICS 66 225D Digital Scale Diagnostics 66 On Scre...

Page 7: ...10 SCALE IS UNSTABLE 110 LOAD CELL OR SCALE COMMUNICATION PROBLEMS 111 iSITE CONFIGURATION 112 225D iSite Configuration 112 iSite Status of Last Connection 113 825D iSite Configuration 114 iSite Statu...

Page 8: ...0330 0410 0M Rev D Portable Digital Truck Scale VI...

Page 9: ...sy because there are no junction boxes used in the scale and the digital load cells plug and play with each other and provide digital diagnostics for each individual load cell at the indicator The NTE...

Page 10: ...are not certain for which voltage level your scale is configured Power Outlet Your weighing system will require one or more power outlets Refer to Table A to determine the number of power outlets nece...

Page 11: ...ilding itself These disturbances result from switching heavily inductive loads such as welders motors and solenoids These sources of disturbances must be identified and steps taken to prevent possible...

Page 12: ...1 and neutral or L2 wires in the run from the distribution panel to the weighing system power outlets The size of the ground wire must comply with The National Electrical Code or local electrical code...

Page 13: ...nge of temperatures In order to keep equipment cooling requirements to a minimum the equipment should be placed out of direct sunlight and in an area where air is free to flow around all sides of the...

Page 14: ...0330 0410 0M Rev D Portable Digital Truck Scale 6 Scale Site Cont...

Page 15: ...ale installed in any one location for a period of six months or more on the approach end or ends there shall be a straight and level approach as follows A At least the width of the platform B At least...

Page 16: ...to Final Assembly Drawing Optional Lifting Lugs Lifting Lugs are available for the lifting of scale sections Note that the lifting lugs are shipped on the last module loaded on the truck at the factor...

Page 17: ...aps for transporting IMPORTANT Do not remove the shipping straps and load cell shipping brackets until the sections are connected together and the scale is secured to the concrete slab or piers The ca...

Page 18: ...t 3 inches apart Establish the centerline of the slab or pier per the pier plan drawing Per the pier plan drawing snap a lateral chalk line for aligning the lower frame 2 Set the first scale section E...

Page 19: ...is on the end chalk line and the edge of the lower frame aligns with the chalk line offset from the centerline 5 To set the drop in weighbridge between the end bridges on an installation using the opt...

Page 20: ...on lower frame base spacers between the end weighbridges Refer to the weighbridge schematic drawing for details The lower frame base spacers are installed between the end weighbridges With the end wei...

Page 21: ...4 and 6 NOTE Be sure to install the end node terminator on the load cell at end of the loop as shown 1 Remove the cable trays and position the load cell cable out of the way to gain access to the ship...

Page 22: ...load cells Install the load cell cable connectors on the load cell fittings and hand tighten the connectors If needed insert load cell cable into scale conduit Install load cell cable connectors on lo...

Page 23: ...between the 225D or 825D indicator and the first load cell in the loop Start Node Consult the chart below to determine the maximum Homerun Cable length Note that the number of load cells in the scale...

Page 24: ...in spring cage connector from the Home Run Cable Connector Pack Refer to the table below for cable and connector information Cable and Connector Information ITEM and DESCRIPTION CARDINAL PART NO HOMER...

Page 25: ...el and main housing Lay the rear panel on the workbench next to the indicator IMPORTANT You may need to loosen the gland connectors for the I O cables to allow enough slack in the cable and wires to a...

Page 26: ...Wire Color Wire Color if using a Load Cell Cable SHLD GRAY BROWN V BUS RED WHITE V BUS BLACK BLUE CAN H WHITE BLACK CAN L BLUE or LIGHT BLUE GRAY 8 Using a small flat blade screwdriver press down on t...

Page 27: ...el with the fourteen acorn nuts removed earlier following a diagonal pattern when tightening the acorn nuts 4 Using a wrench tighten the plastic gland connectors to 15 in lb 1 7 Nm 5 Using a wrench ti...

Page 28: ...ustomer the jumpers must be OFF on one pin only or removed IMPORTANT In order to operate from an external power source the jumpers must be OFF on one pin only or removed and 12 to 24 VDC must be appli...

Page 29: ...between the panel and main housing Lay the rear panel on the workbench next to the indicator IMPORTANT You may need to loosen the gland connectors for the I O cables to allow enough slack in the cable...

Page 30: ...bar will return to its original position locking the wire in place 10 Repeat steps 8 and 9 until all five wires of the homerun cable are installed in the P1 terminal block on the 825DLC controller ca...

Page 31: ...MB AC media box or an external 12 to 24 VDC power supply provided by the customer the jumpers must be OFF on one pin only or removed IMPORTANT In order to operate from an external power source the jum...

Page 32: ...using a Load Cell Cable SHLD GRAY BROWN V BUS RED WHITE V BUS BLACK BLUE CAN H WHITE BLACK CAN L BLUE or LIGHT BLUE GRAY Micro USB This connector is used to perform firmware updates to the 825 DLC con...

Page 33: ...OMERUN CABLE BELDEN 5303FE 18 AWG 5 CONDUCTOR SUPPLIED BY DEALER IMPORTANT Clean the load cell connectors and the homerun connector plug with electrical contact cleaner and then apply dielectric greas...

Page 34: ...LIGHT BLUE GRAY 4 Looking at the end of the metal part of the connector where the wires are inserted use your fingernail and gently pull a wire clamp lever down away from the body of the connector 5 I...

Page 35: ...nd metal parts of the connector housing and then hand tighten the cable clamp to the black plastic part of the connector housing NOTE For reference the image below shows the cable clamp separated from...

Page 36: ...the ground rod through the pier prior to pouring the concrete 3 Connect the weighbridge to the ground rod with a minimum 1 5 38 mm braided cable or ground wire 4 Connect the grounding lug on the indic...

Page 37: ...ps 1 Replace the cable tray removed earlier 2 Roll up any excess load cell cable and place on the cable tray 3 Make sure the cables are clear of the access plate opening 4 Place one side of access pla...

Page 38: ...ferred For example in the illustration below the connection loop begins with load cell 4 and runs clockwise ending with the end node terminator on load cell 6 Also note that there is not a connection...

Page 39: ...L 1 SCALE 1 ID 1D7A173F START 2 CELL 2 SCALE 1 ID 0EB0EBFF END 3 CELL 3 SCALE 1 ID 18B8783F 4 CELL 4 SCALE 1 ID 09C99FFF Enter Selection 0 NEXT EXIT END NODES EXIT 6 Press a cell number and then ENTER...

Page 40: ...ted and the auto zero function turned off Refer to the 225 Weight Indicator Installation and Technical Manual All digital cells are pre calibrated for span in the factory That means that span calibrat...

Page 41: ...press ENTER to take a weight sample 7 Repeat steps 5 6 for each cell in the order that the 225D prompts for This is the same order as other Cardinal scales e g 1 3 5 7 8 6 4 2 ZERO CALIBRATION Zero C...

Page 42: ...ll prompt ENTER NEW WEIGHT 8 Enter the actual correct weight of the test weight and press ENTER 9 The 225D will automatically trim cell to match the entered test weight 10 Press the PREVIOUS and NEXT...

Page 43: ...he main board is loaded with the DLC version of software The Slot Type is showing that Slot 1 of the 825D is occupied by a DLC card version 1 00 001 NOTE Currently the 825D only supports a single DLC...

Page 44: ...to proceed with Setup and Configuration NOTE The 825D will arrive from the factory with the calibration access locked by the login and password prompts protection The factory default login and passwor...

Page 45: ...Setup Scale Number Setup Scale Number With the Setup Scale Number screen displayed press the D key or use the Navigation Keys to select highlight D Configure DLC and then press the ENTER key The displ...

Page 46: ...e chain of load cells iSITE SO Set Sales Order or other identifier for communications link to iSite cloud DHCP Yes for automatic configuration of the DLC card Ethernet parameters from a DHCP server No...

Page 47: ...C Card 1 Cell Assignment The left side of the column shows the existing programmed IDs and scale number assigned for each cell If any cells are detected on the bus that are not assigned they will show...

Page 48: ...ed column The left navigation key may be used to select the existing cell IDs The up down navigation keys may be used to select a specific cell Assign Cell Select the next cell to assign on the right...

Page 49: ...Rev D Portable Digital Truck Scale 41 DLC Card 1 Cell Assignment Cont Cell IDs may also be entered manually and the scale to associate with the cell by selecting an item in the left column pressing t...

Page 50: ...le number When finished press and release the SHIFT key then press the ESC key The display will return to the Setup Scale Number screen NOTE If the DLC configuration changes have changed the number of...

Page 51: ...ect highlight 2 Smart Calibration and then press the ENTER key The display will change to show the Scale 1 Smart Calibration screen IMPORTANT Before calibrating the scale it is very important that the...

Page 52: ...0330 0410 0M Rev D Portable Digital Truck Scale 44 Smart Calibration Cont With the Scale 1 Smart Calibration screen displayed enter the weight value of the test weight to be used...

Page 53: ...0330 0410 0M Rev D Portable Digital Truck Scale 45 Smart Calibration Cont With an empty scale press ENTER This will capture the calibrated dead load weight of the scale...

Page 54: ...0330 0410 0M Rev D Portable Digital Truck Scale 46 Smart Calibration Cont The 825D display will change to show that it is calibrating...

Page 55: ...0330 0410 0M Rev D Portable Digital Truck Scale 47 Smart Calibration Cont Center the weight over load cell 1 and press ENTER...

Page 56: ...0330 0410 0M Rev D Portable Digital Truck Scale 48 Smart Calibration Cont The 825D display will change to show that it is calibrating the weight on load cell 1...

Page 57: ...ev D Portable Digital Truck Scale 49 Smart Calibration Cont Move the test weight and center it over load cell 2 and press ENTER The 825D display will change to show that it is calibrating the weight o...

Page 58: ...ev D Portable Digital Truck Scale 50 Smart Calibration Cont Move the test weight and center it over load cell 3 and press ENTER The 825D display will change to show that it is calibrating the weight o...

Page 59: ...e to show that it is calibrating the weight on load cell If more than four cells and the number of cells is even a number such as for an eight cell scale the calibration pattern will be the odd number...

Page 60: ...bration 3 Zero Calibration With the Scale 1 Calibration Options screen displayed press the 3 key or use the Navigation Keys to select highlight 3 Zero Calibration and then press the ENTER key The disp...

Page 61: ...ev D Portable Digital Truck Scale 53 Zero Calibration Cont With an empty scale press ENTER Zero Calibration does not affect the trimming of the cells or affect span it simply sets the dead load weight...

Page 62: ...0330 0410 0M Rev D Portable Digital Truck Scale 54 Zero Calibration Cont The 825D display will change to show that it is calibrating zero...

Page 63: ...im Cells 4 Trim Load Cells With the Scale 1 Calibration Options screen displayed press the 3 key or use the Navigation Keys to select highlight 4 Trim Load Cells and then press the ENTER key The displ...

Page 64: ...of cells may be trimmed This requires a test load weight M ode Press the M key to toggle between Section or Single Cell trim Default is Section Use the Navigation Keys to select highlight the section...

Page 65: ...0330 0410 0M Rev D Portable Digital Truck Scale 57 Trim Cells Cont Single Cell Mode Press the M key to select Single Cell trim Use the Navigation Keys to select highlight the cell to trim...

Page 66: ...0330 0410 0M Rev D Portable Digital Truck Scale 58 Trim Cells Cont Single Cell Mode Cont With the desired cell selected enter the Trim Value and press the ENTER key to set the weight to adjust trim...

Page 67: ...0330 0410 0M Rev D Portable Digital Truck Scale 59 Trim Cells Cont Single Cell Mode Cont The 825D will automatically trim the cell to match the entered weight...

Page 68: ...Mode Cont NOTE If in the Single Cell mode manually enter a trim value by pressing the FUNCT key then press the period key This can be used to enter a slight adjustment such as change 0 98411 to 0 9842...

Page 69: ...Span Adjust 5 Span Adjust With the Scale 1 Calibration Options screen displayed press the 3 key or use the Navigation Keys to select highlight 5 Span Adjust and then press the ENTER key The display w...

Page 70: ...62 Span Adjust Span adjust allows you to tweak the span of the entire scale at once The 825D will display the current live scale weight Place the test weight at any location on the scale Enter the va...

Page 71: ...D Portable Digital Truck Scale 63 Span Adjust After a brief delay the span will be adjusted trim will be adjusted for all cells of the scale and the 825D display will return to the Scale 1 Calibratio...

Page 72: ...d be carrying an equal dead load of plus or minus 10 percent 3 If a cell in a section has an output less than 20 percent of the cell carrying the most load jack the weighbridge up loosen the load cell...

Page 73: ...0M Rev D Portable Digital Truck Scale 65 Install shims between the load cell pivot plate and the weighbridge load cell block to evenly distribute the deadload Insert Shim Here Insert Shim Here Insert...

Page 74: ...o iSite will also receive all of the hardware errors found by the indicator Hardware Diagnostics LEDs on the DLC controller alert technicians of communications status On Screen Diagnostics The followi...

Page 75: ...RESPONDING Probable Cause Items to Check The 225D cannot detect the exact communication problem with the unresponsive load cell Check that cable is connected correctly Check cable for damage Verify t...

Page 76: ...cale is not Legal For Trade and will need to be calibrated MORE LOAD CELLS THAN EXPECTED Probable Cause Items to Check There are more load cells than expected connected to the 225D For example the num...

Page 77: ...a scale to the load cell LOW VOLTAGE DETECTED ON LOAD CELL X Y Z Probable Cause Items to Check Low power on a load cell Load cells at the end of the CAN daisy chain are most susceptible to low voltage...

Page 78: ...5D cannot communicate with the option card or the option card is not responding Check that the card is seated properly and fastened correctly Check that card is seated on the correct row of pins Poten...

Page 79: ...M MINIMUM WEIGHTS 1 0 0 6 0 0 2 0 0 7 0 0 3 0 0 8 0 0 4 0 0 5 0 0 PREVIOUS NEXT EXIT Zeroing the LIVE LOAD CELL WEIGHTS and MINIMUM AND MAXIMUM WEIGHTS screens is only temporary while in diagnostics I...

Page 80: ...0 14 6 1 0 14 2 1 0 14 7 1 0 14 3 1 0 14 8 1 0 14 4 1 0 14 5 1 0 14 PREVIOUS NEXT EXIT NOTE The controller s version number in contrast is displayed upon startup of the 225D indicator LOADCELL COMMUNI...

Page 81: ...messages from the DLC card buffer that were not kept up with This should not happen unless too many cells are connected with too high of a sample rate Bus Off This does not happen if you completely di...

Page 82: ...ndicates the cell voltage measurement was not calibrated but is an approximate value based on the raw counts The 0 184 Amps in this example shows the approximate current draw from the DLC for all of t...

Page 83: ...e same channel that the indicator is set to This screen shows the ID of the SmartMedia Box the channel that is being used and the signal strength detected at the SnapComD and SmartMedia Box SNAP COMMU...

Page 84: ...ELL Toggles each time the controller receives a response from some or all of the load cells Blinking does not mean that it got a response from EVERY load cell If some load cell does not respond the in...

Page 85: ...ator selects YES then the 225D mainboard will upload the scale configuration to the controller and the indicator will immediately be able to make weight again 225D MAIN PCB REPLACEMENT If a 225D main...

Page 86: ...D Portable Digital Truck Scale 78 225DLC Digital Controller Card Replacement Align pins on 225DLC card with holes in P2 Remove the remaining three screws and lock washers Remove this screw washer and...

Page 87: ...connector P2 on the main board and apply even downward pressure to the edge of the 225DLC card 8 Align the holes in the 225DLC with the threaded mounting spacers on the main board 9 Secure the 225DLC...

Page 88: ...perator on the main weight screen in real time when the error happens COMMUNICATION ERROR BETWEEN INDICATOR AND SCALE Probable Cause Items to Check The homerun cable is damaged or disconnected Check t...

Page 89: ...ERROR BETWEEN LOAD CELLS X AND Y Probable Cause Items to Check There is a loss of communication between load cells Check that cable is connected correctly Check cable for damage Verify that connector...

Page 90: ...Z NOT RESPONDING Probable Cause Items to Check The 825D cannot detect the exact communication problem with the unresponsive load cell Check that cable is connected correctly Check cable for damage Ver...

Page 91: ...ow power on a load cell Load cells at the end of the CAN daisy chain are most susceptible to low voltage errors because of voltage drop along the cable Too many load cells on the chain Check that cabl...

Page 92: ...that give a technician more information about each load cell 6 DLC Diagnostics With the Scale 1 Calibration Options screen displayed press the 6 key or use the Navigation Keys to select highlight 6 DL...

Page 93: ...ev D Portable Digital Truck Scale 85 LIVE LOAD CELL WEIGHTS Use the Navigation Keys to scroll the display to show all cells Press the W key to jump to the Load Cell Weights screen from the other diagn...

Page 94: ...The Z key for Zero may be used to zero the diagnostics display while in the diagnostics screen It does not affect scale zero Use the Navigation Keys to scroll the display to show all cells Press the W...

Page 95: ...Portable Digital Truck Scale 87 MINIMUM AND MAXIMUM WEIGHTS Use the Navigation Keys to scroll the display to show all cells Press the X key to jump to the Maximum Minimum Weights screen from the other...

Page 96: ...from the original calibrated deadload An asterisk indicates that the deadload shift has been exceeded Scale must empty for this to be valid Use the Navigation Keys to scroll the display to show all c...

Page 97: ...le Digital Truck Scale 89 LOAD CELL IDS SOFTWARE VERSIONS Use the Navigation Keys to scroll the display to show all cells Press the R key to jump to the Load Cell IDs Software Versions screen from the...

Page 98: ...gital Truck Scale 90 LOAD CELL COMMUNICATION ERROR COUNTS Use the Navigation Keys to scroll the display to show all cells Press the E key to jump to the Load Cell Communication Error Counts screen fro...

Page 99: ...CELL COMMUNICATION ERROR COUNTS Use the Navigation Keys to scroll the display to show all cells Press the C key to clear the Communication Error Counts Press the E key to jump to the Load Cell Communi...

Page 100: ...Error Counts are analog errors that would normally indicate a bad cell Use the Navigation Keys to scroll the display to show all cells Press the C key to clear the Weight Error Counts Press the G key...

Page 101: ...k Scale 93 LOAD CELL TEMPERATURES This is the temperature of the cells in Celsius Use the Navigation Keys to scroll the display to show all cells Press the T key to jump to the Load Cell Temperatures...

Page 102: ...le Digital Truck Scale 94 LOAD CELL MINIMUM MAXIMUM TEMPS Use the Navigation Keys to scroll the display to show all cells Press the Q key to jump to the Load Cell Maximum Minimum Temps screen from the...

Page 103: ...ev D Portable Digital Truck Scale 95 LOAD CELL MILLIVOLTS Use the Navigation Keys to scroll the display to show all cells Press the M key to jump to the Load Cell Millivolts screen from the other diag...

Page 104: ...Digital Truck Scale 96 LOAD CELL ABSOLUTE MAXIMUM WEIGHTS Use the Navigation Keys to scroll the display to show all cells Press the O key to jump to the Load Cell Absolute Maximum Weights screen from...

Page 105: ...OUNT VOLTAGE NOTE An asterisk indicates voltage determination is approximated based on raw count value Use the Navigation Keys to scroll the display to show all cells Press the V key to jump to the Su...

Page 106: ...ev D Portable Digital Truck Scale 98 LOAD CELL RAW COUNTS Use the Navigation Keys to scroll the display to show all cells Press the R key to jump to the Load Cell Raw Counts screen from the other diag...

Page 107: ...stic purposes D1 Blinking Indicates the 825 DLC card is communicating with the 825D main board D2 Blinking Indicates the 825 DLC card is transmitting messages is to the load cells D3 Blinking Indicate...

Page 108: ...aced or the mainboard was replaced and then reconfigure the NEW card to the existing scale 825D DLC DIGITAL CONTROLLER CARD REPLACEMENT If an option card is replaced the 825D will boot up to this scre...

Page 109: ...controller to the main board If the operator selects YES then the scale configuration will be downloaded from the controller to the mainboard Scale configuration includes number of load cells all load...

Page 110: ...LC card to the main PC board and then lift the 825 DLC straight up to remove it from the enclosure 5 Disconnect the Homerun cable wires and any other wires or cables from the 825 DLC card 6 On the new...

Page 111: ...825D will check whether the option card has been replaced in order to reconfigure the new option card to the existing scale 14 If the operator selects Y then the 825D main board will upload the scale...

Page 112: ...e the truck on the scale and take a reading B Remove the truck turn around and re enter the scale C The readings must repeat within 0 2 percent of the applied load Example 80 000 lb truck the readings...

Page 113: ...ommended solutions to those problems DISPLAYED ERROR MESSAGES REPLACE LOAD CELL X SOLUTION A Using a NEST test the load cell B If the load cell fails the test on the NEST replace the indicated load ce...

Page 114: ...roximately 250 milliamps Tolerance is 15 milliamps On the 825D you should read approximately 250 milliamps of current through an 8 load cell system each load cell will pull approximately 30 milliamps...

Page 115: ...200 milliamps of current through an 8 load cell system each load cell will pull approximately 25 milliamps A 10 load cell system would read approximately 250 milliamps Tolerance is 15 milliamps On th...

Page 116: ...of the load cell IDs and their corresponding scale locations NOT the location in the data loop C If a Cardinal Digital Load Cell Simulator is available remove the Homerun cable from the first load ce...

Page 117: ...tion If the load cell fails to respond replace the load cell J Next connect the next load cell in the loop Go to the Scale Setup screen and enter Number of Cells 2 Enter the ID for the second load cel...

Page 118: ...eck is clear of any buildup or debris enter DIAGNOSTICS B The first screen displays the actual deadload that is on each load cell If these values look correct push the ZERO key to get a zero reading f...

Page 119: ...cs screen LOAD CELL COMMUNICATIONS ERRORS and observe the historical error counters for each load cell B Record these numbers C Press EXIT to zero the counters on the 225D For the 825D press C lear to...

Page 120: ...ealer account In many cases DHCP may be used in which case setup is quite simple 1 SO XXXXXX 2 DHCP YES If a static IP address is required such as to address firewall issues then set DHCP NO and promp...

Page 121: ...T DETECTED or ETHERNET NOT DETECTED C The status of the connection The following statuses should occur in order while making a connection after boot up a WAITING FOR SOCKET INIT b IP BINDING c DNS RES...

Page 122: ...used by the server to determine if there are problems with the scale s that need to be addressed With the Scale 1 Calibration Options screen displayed press the 6 key or use the Navigation Keys to se...

Page 123: ...115 825D iSite Configuration Cont ISITE STATUS OF LAST CONNECTION If IP BINDING message is displayed for a long time it may indicate no network connection is present WAITING FOR SOCKET INIT PORT CONN...

Page 124: ...0330 0410 0M Rev D Portable Digital Truck Scale 116 825D iSite Configuration Cont ENTER VALID SO IDENTIFIER FOR ISITE Make sure valid SO identifier is entered for iSite...

Page 125: ...0330 0410 0M Rev D Portable Digital Truck Scale 117 825D iSite Configuration Cont SUCCESSFUL COMM ESTABLISH FOR ISITE The 825D screen will display OKAY when a successful comm has been establish...

Page 126: ...0330 0410 0M Rev D Portable Digital Truck Scale 118 PARTS IDENTIFICATION...

Page 127: ...30 0410 0M Rev D Portable Digital Truck Scale 119 Weighbridge Assembly Quantity shown for 70 x 11 scale See Grounding Detail See Detail D Lower Frame Base Spacer Assembly Detail See Optional Lifting L...

Page 128: ...vailable for the lifting of scale sections Note that the lifting lugs are shipped on the last section loaded on the truck at the factory Modifications at the factory to the steel deck are required to...

Page 129: ...0 0036 1 GROUND WIRE 1 1 2 FLAT BRAID 3 AWG 6980 0035 1 WIRE 10GA STRANDED GREEN 6610 5023 2 GOUNDING CLAMP Lower Frame Base Spacer Assembly Detail 6 8 6024 0051 LOCK WASHER 1 2 HELICAL SPRING 7 8 600...

Page 130: ...2 Lower Frame Bolt Down Anchor Assembly Detail NO QTY ITEM DESCRIPTION 3 8 0330 0197 08 BOLT DOWN ANGLE HR ANG 4 X 4 X 3 16 X 4 4 8 6007 0361 HEX HEAD BOLT 1 8 UNC 2A X 2 1 2 5 8 6024 0060 LOCK WASHER...

Page 131: ...MBLY 2 1 0331 0066 0A WEIGHBRIDGE END MODULE 3 4 0330 0216 0A LOAD CELL STAND ASSEMBLY 4 8 0330 0125 18 PIVOT PLATE TS FB 3 8 X 1 3 8 ANNEALED A 2 5 8 6007 0009 HEX HEAD BOLT 1 4 20 UNC 2A X 1 2 Z P 6...

Page 132: ...WG AND 1 x 22AWG 3502 0681 0A 1 CONNECTOR PACK HOME RUN CABLE INCLUDES 5 PIN SPRING CAGE CONNECTOR 6610 1258 0330 0065 08 2 INTERCONNECT CABLE 15 4572mm 22AWG 0330 0066 08 5 INTERCONNECT CABLE 27 8230...

Page 133: ...0330 0410 0M Rev D Portable Digital Truck Scale 125 Decal and Name Plate Mounting View Detail...

Page 134: ...x 11 scale NO QTY ITEM DESCRIPTION 4 2 5930 D091 08 NAME PLATE 5 12 6680 0210 POP RIVET 10 2 0145 B453 08 DECAL REMOVE SHIPPING ASSEMBLY 11 2 0145 B393 08 DECAL CAUTION DO NOT WELD 12 1 0145 B392 18 D...

Page 135: ...purchased with Guardian Vehicle Scale LIFE YES YES YES YES 90 DAYS 1 5 6 8 A B C D HYDRAULIC LOAD CELLS When purchased separately 10 YEARS YES YES YES YES NO 1 5 6 8 9 A B C D VEHICLE SCALE Deck and...

Page 136: ...any item that has been damaged due to unusual wear abuse improper line voltage overloading theft re water prolonged storage or exposure while in purchaser s possession or acts of God unless otherwise...

Page 137: ...0330 0153 0M Rev A Digital Truck Scale 39...

Page 138: ...le 40 Cardinal Scale Mfg Co 203 E Daugherty Webb City MO 64870 USA Ph 417 673 4631 or 1 800 641 2008 Fax 417 673 2153 www cardinalscale com Technical Support 1 866 254 8261 E mail tech cardet com 0330...

Reviews: