0330-0410-0M Rev D
•
Portable Digital Truck Scale
14
3.
If needed, run the load cell cables through the conduit installed in the bridges between
the load cells. Install the load cell cable connectors on the load cell fittings, and hand-
tighten the connectors.
If needed, insert load cell cable into
scale conduit.
Install load cell cable connectors on
load cell fittings and hand-tighten.
4.
Install the End Node Terminator on the last cell of the loop.
Install End Node Terminator.
End Node
Terminator