0330-0410-0M Rev D
•
Portable Digital Truck Scale
64
Balancing Weighbridge Dead Load
Before calibration, it is very important that the dead load of the weighbridge be evenly
distributed between the pair of cells in a section.
1.
Begin by powering up the indicator and proceeding to the Diagnostics Menu to the
LOADCELL WEIGHTS screen on the 225D or the LIVE LOAD CELL WEIGHTS on the
825D.
2.
Each pair of load cells should be carrying an equal dead load of plus (+) or minus (-) 10
percent.
3.
If a cell in a section has an output less than 20 percent of the cell carrying the most load,
jack the weighbridge up, loosen the load cell mounting bolt as well as the load cell pivot
plate retaining bolt, and place a factory supplied shim (0330-0148-08, 7 GA. LOAD CELL
SHIM) or (0330-0149-08, 10 GA. LOAD CELL SHIM) between the load cell pivot plate, and
the weighbridge load cell block.
Loosen load cell mounting bolt, and load cell pivot plate retaining bolt, then
insert porta-power jack into opening to lift weighbridge to add shims.
Porta-Power
Jack Opening